The Circuit Breaker, cataloged under National Stock Number 5925-01-283-2930, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 28 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-283-2930 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Bushing Length | 0.468 INCHES NOMINAL IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC AND 50.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED STUD(S) |
| Frequency in Hertz | 50.0 OR 60.0 SINGLE LOCATION |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 135.0 SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.680 INCHES NOMINAL IN |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 1.555 INCHES NOMINAL IN |
| Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC AND 1000.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.500 INCHES IN |
| Body Length | 1.375 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 3.000 MINIMUM AT 135 PCT AND 70.000 MAXIMUM AT 135 PCT AND 2.000 MINIMUM AT 150 PCT AND 40.000 MAXIMUM AT 150 PCT AND 1.000 MINIMUM AT 200 PCT AND 15.000 MAXIMUM AT 200 PCT AND 0.100 MINIMUM AT 400 PCT AND 4.000 MAXIMUM AT 400 PCT AND 0.008 MINIMUM AT 600 PCT AND 2.000 MAXIMUM AT 600 PCT AND 0.006 MINIMUM AT 800 PCT AND 0.800 MAXIMUM AT 800 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Inclosure Protection Type for Which Designed | SHOCK RESISTANT AND VIBRATION RESISTANT |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 2 TAB, SOLDER LUG |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Thread Series Designator | UN |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Center to Center Distance Between Terminals Parallel to Length | 1.125 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| T11-2-3.00A-02-20A | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-283-2930 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-283-2930: Bushing Length: 0.468 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC AND 50.0 DC SINGLE LOCATION. 28 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.