The Circuit Breaker, cataloged under National Stock Number 5925-01-282-4591, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 2 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-282-4591 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 2 THREADED HOLE(S) |
| Actuator Position Designation | AT POLE ONE |
| Frequency in Hertz | 50.0 OR 60.0 SINGLE LOCATION |
| Unpackaged Unit Weight | 2.500 OUNCES NOMINAL OZ |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SINGLE LOCATION |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 1.628 INCHES MINIMUM AND 1.692 INCHES MAXIMUM IN |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.718 INCHES MINIMUM AND 0.782 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 1.898 INCHES MINIMUM AND 1.962 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC SINGLE LOCATION |
| Features Provided | HIGH INRUSH PROTECTION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC SINGLE LOCATION |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 1.968 INCHES MINIMUM AND 2.032 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 15.000 MINIMUM AT 200 PCT AND 70.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT AND MOISTURE RESISTANT |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 2 QUICK DISCONNECT, MALE |
| Special Handling Feature | MAGNETIC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| IPG1-9199-1-V | 5/2 Secondary reference U.S. Government activity |
| JA1S-A8-AR-01-W-APN-10-10 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
| 107782 | 3/9 Design control — primary reference Intel Corp Sales Office |
NSN 5925-01-282-4591 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
2 possible matches (shared part number, not a government interchangeability claim): 5935-01-643-4409, 5995-01-663-9755. Verify interchangeability with system specifications before substitution.
Key specifications for 5925-01-282-4591: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.