The Circuit Breaker, cataloged under National Stock Number 5925-01-281-6504, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-281-6504 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Bushing Length | 0.625 INCHES NOMINAL IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SECOND LOCATION |
| Internal Trip Release Configuration | SERIES TRIP THIRD LOCATION |
| Internal Trip Release Configuration | SERIES/RELAY TRIP FIRST LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL AND 6 THREADED HOLE(S) |
| Actuator Position Designation | AT POLE TWO |
| Unpackaged Unit Weight | 9.000 OUNCES NOMINAL OZ |
| Center to Center Distance Between Terminals Parallel to Width | 0.651 INCHES MINIMUM AND 0.661 INCHES MAXIMUM IN |
| Nonturn Device Radius | 0.656 INCHES NOMINAL IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 115.0 ALL LOCATIONS |
| Nonturn Device Length | 0.130 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 2.250 INCHES NOMINAL IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Trip Release Duty Cycle | CONTINUOUS FIRST LOCATION |
| Pole Quantity | 3 |
| Mounting Surface to Terminal End Distance | 2.232 INCHES MAXIMUM IN |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 3500.0 AC ALL LOCATIONS |
| Nominal Thread Size | 0.500 INCHES AND 0.138 INCHES IN |
| Body Length | 2.000 INCHES NOMINAL IN |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Inclosure Protection Type for Which Designed | CORROSION RESISTANT AND MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF |
| Nonturn Device Diameter | 0.151 INCHES MINIMUM AND 0.161 INCHES MAXIMUM IN |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Auxiliary Trip Coil Voltage Type and Rating in Volts | 115.0 AC NOMINAL FIRST LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| APGN-662-22005-2 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-281-6504 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-281-6504: Bushing Length: 0.625 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION; Internal Trip Release Configuration: SERIES TRIP THIRD LOCATION. 29 specifications are documented in the U.S. Government catalog.