The Circuit Breaker, cataloged under National Stock Number 5925-01-274-1290, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is General Dynamics Mission Systems, Inc.. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-274-1290 |
| Primary Part Number | 29-1330393-2 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | General Dynamics Mission Systems, Inc. |
| Status | ACTIVE |
| Bushing Length | 0.250 INCHES NOMINAL IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 32.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING |
| Actuator Position Designation | AT POLE ONE |
| Switch Terminal Type | TAB, SOLDER LUG |
| Unpackaged Unit Weight | 2.000 OUNCES NOMINAL OZ |
| Body Style | SINGLE POLE TYPE |
| Switch Voltage Rating and Type in Volts | 28.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SINGLE LOCATION |
| Switch Location and Position Designation | INTERNAL AT POLE ONE |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.656 INCHES NOMINAL IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 1.669 INCHES NOMINAL IN |
| Maximum Continuous Load Current Rating Per Pole | 250.0 MILLIAMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | INSTANTANEOUS SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 2500.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.469 INCHES IN |
| Body Length | 1.781 INCHES NOMINAL IN |
| Manual Actuator Type and Quantity | 1 PUSH-PULL |
| Switch Current Rating and Type in Amps | 7.0 DC |
| Inclosure Protection Type for Which Designed | DUSTPROOF AND CORROSION RESISTANT AND FUNGUS RESISTANT AND SAND RESISTANT |
| Switch Contact Arrangement | SINGLE POLE, DOUBLE THROW |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 2 TAB W/SCREW |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 29-1330393-2 PRIMARY | General Dynamics Mission Systems, Inc. (USA) |
| Reference | Meaning |
|---|---|
| 29-1330393-2 | 3/9 Design control — primary reference Gte Government Systems Corp Strategic Systems Div |
| 7MC3-3-0.250 | 5/2 Secondary reference U.S. Government activity |
NSN 5925-01-274-1290 is a Circuit Breaker, manufactured by General Dynamics Mission Systems, Inc., classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-274-1290 has 1 manufacturer part number on file: 29-1330393-2 (General Dynamics Mission Systems, Inc.).
Key specifications for 29-1330393-2: Bushing Length: 0.250 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 32.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.