The Circuit Breaker, cataloged under National Stock Number 5925-01-270-5258, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Raytheon Company Div Rmd Strategic. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-270-5258 |
| Primary Part Number | 711584-1 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Raytheon Company Div Rmd Strategic |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SECOND LOCATION |
| Internal Trip Release Configuration | SERIES TRIP FIRST LOCATION |
| Internal Trip Release Configuration | SHUNT TRIP THIRD LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC FIRST LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC SECOND LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 115.0 AC AND 240.0 AC THIRD LOCATION |
| Mounting Facility Type and Quantity | 6 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Unpackaged Unit Weight | 0.547 POUNDS NOMINAL LBS |
| Center to Center Distance Between Terminals Parallel to Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT FIRST LOCATION |
| Circuit Protection Type | OVERCURRENT SECOND LOCATION |
| Circuit Protection Type | UNDERVOLTAGE THIRD LOCATION |
| Body Width | 2.205 INCHES MINIMUM AND 2.285 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 3 |
| Mounting Surface to Terminal End Distance | 2.553 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 40.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC ALL LOCATIONS |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 2.510 INCHES MAXIMUM IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 711584-1 PRIMARY | Raytheon Company Div Rmd Strategic (USA) |
| Reference | Meaning |
|---|---|
| AM3-Z342-2 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
| APL-112-7719-1 | 5/2 Secondary reference U.S. Government activity |
NSN 5925-01-270-5258 is a Circuit Breaker, manufactured by Raytheon Company Div Rmd Strategic, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-270-5258 has 1 manufacturer part number on file: 711584-1 (Raytheon Company Div Rmd Strategic).
1 possible match (shared part number, not a government interchangeability claim): 5935-01-343-9377. Verify interchangeability with system specifications before substitution.
Key specifications for 711584-1: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION; Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION; Internal Trip Release Configuration: SHUNT TRIP THIRD LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.