The Circuit Breaker, cataloged under National Stock Number 5925-01-268-3175, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 16 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-268-3175 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Bushing Length | 0.625 INCHES NOMINAL IN |
| Reset Method | MANUAL |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC SINGLE LOCATION |
| Frequency in Hertz | 400.0 SINGLE LOCATION |
| Center to Center Distance Between Terminals Parallel to Width | 1.530 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Body Width | 2.000 INCHES NOMINAL IN |
| Pole Quantity | 3 |
| Mounting Surface to Terminal End Distance | 2.232 INCHES NOMINAL IN |
| Maximum Continuous Load Current Rating Per Pole | 15.00 AMPERES AC SINGLE LOCATION |
| Specification/standard Data | 81349MIL-C-55629/22 GOVERNMENT SPECIFICATION |
| Body Length | 2.265 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 20.000 MINIMUM AT 200 PCT AND 160.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Test Data Document | 81349-MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| MIL-C-55629/22 | 5/9 Secondary reference U.S. Government activity |
| M55629/22RSRSRS | 2/2 Government specification standardization U.S. Government activity |
| MIL-PRF-55629/22 | 4/1 Identification reference U.S. Government activity |
NSN 5925-01-268-3175 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-268-3175: Bushing Length: 0.625 INCHES NOMINAL IN; Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC SINGLE LOCATION; Frequency in Hertz: 400.0 SINGLE LOCATION. 16 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.