The Circuit Breaker, cataloged under National Stock Number 5925-01-264-6569, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Bryant Electric. Government technical data includes 28 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-264-6569 |
| Primary Part Number | BR250 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Bryant Electric |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 2 CLIP |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 1.000 INCHES NOMINAL IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 140.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE AND TWO LINKED |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 2.000 INCHES NOMINAL IN |
| Body Height | 2.370 INCHES NOMINAL IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 2 |
| Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 22000.0 AC ALL LOCATIONS |
| Body Length | 2.910 INCHES NOMINAL IN |
| Manual Actuator Type and Quantity | 2 TOGGLE |
| Inclosure Protection Type for Which Designed | GENERAL PURPOSE |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Trip Release Ambient Temp Rating | 40.0 CELSIUS NOMINAL ALL LOCATIONS DEGC |
| Terminal Type and Quantity | 2 CLIP AND 2 COMPRESSION |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Boss Height | 0.188 INCHES NOMINAL IN |
| Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| BR250 PRIMARY | Bryant Electric (USA) |
NSN 5925-01-264-6569 is a Circuit Breaker, manufactured by Bryant Electric, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-264-6569 has 1 manufacturer part number on file: BR250 (Bryant Electric).
1 possible match (shared part number, not a government interchangeability claim): 6650-01-629-5999. Verify interchangeability with system specifications before substitution.
Key specifications for BR250: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 2 CLIP; Actuator Position Designation: AT EACH POLE. 28 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.