The Circuit Breaker, cataloged under National Stock Number 5925-01-264-3230, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Thales Deutschland Gmbh Div Customer Services. Government technical data includes 28 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-264-3230 |
| Primary Part Number | 48853 21050 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Thales Deutschland Gmbh Div Customer Services |
| Status | ACTIVE |
| Bushing Length | 0.380 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 50.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL |
| Actuator Position Designation | AT POLE ONE |
| Ultimate Trip Time Per Pole in Seconds | 0.010 MINIMUM SINGLE LOCATION |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.625 INCHES MAXIMUM IN |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 1.605 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 500.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.375 INCHES IN |
| Body Length | 1.500 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 4.000 MINIMUM AT 125 PCT AND 40.000 MAXIMUM AT 125 PCT AND 0.850 MINIMUM AT 200 PCT AND 4.000 MAXIMUM AT 200 PCT AND 0.010 MINIMUM AT 400 PCT AND 0.500 MAXIMUM AT 400 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Inclosure Protection Type for Which Designed | HERMETICALLY SEALED |
| Thread Quantity Per Inch | 32 |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 2 WIRE HOOK |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Thread Series Designator | UNEF |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Center to Center Distance Between Terminals Parallel to Length | 0.875 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 48853 21050 | Thales Deutschland Gmbh Div Customer Services (DEU) |
| Reference | Meaning |
|---|---|
| AP-MIL-1-1-52-502 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-264-3230 is a Circuit Breaker, manufactured by Thales Deutschland Gmbh Div Customer Services, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-264-3230 has 1 manufacturer part number on file: 48853 21050 (Thales Deutschland Gmbh Div Customer Services).
Key specifications for 48853 21050: Bushing Length: 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC SINGLE LOCATION. 28 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.