PartsTable TECHNICAL DATA SHEET
NSN 5925-01-264-2751Government record, cited

Circuit Breaker5925-01-264-2751

NSN 5925-01-264-2751 · NIIN 012642751
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-264-2751 · 5925012642751 · NIIN 012642751 · 01-264-2751 · FSC 5925 Circuit Breakers · T14-S-SP-7413-1 · 2802961 · AM-336
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.458 INCHES MINIMUM AND 0.478 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES/RELAY TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 32.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING
  • Actuator Position Designation: AT POLE ONE
  • Frequency in Hertz: 50.0 OR 60.0 SINGLE LOCATION
Identification
  • NSN: 5925-01-264-2751
  • NIIN: 012642751
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-264-2751, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-264-2751
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.458 INCHES MINIMUM AND 0.478 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES/RELAY TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts120.0 AC AND 32.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity1 THREADED BUSHING
Actuator Position DesignationAT POLE ONE
Frequency in Hertz50.0 OR 60.0 SINGLE LOCATION
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SINGLE LOCATION
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.670 INCHES MINIMUM AND 0.690 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Trip Release Duty CycleCONTINUOUS SINGLE LOCATION
Pole Quantity1
Mounting Surface to Terminal End Distance1.525 INCHES MINIMUM AND 1.585 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES AC AND 15.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 AC AND 1000.0 DC SINGLE LOCATION
Nominal Thread Size0.500 INCHES IN
Body Length1.350 INCHES MINIMUM AND 1.400 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.100 MINIMUM AT 200 PCT AND 2.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedSHOCK RESISTANT AND VIBRATION RESISTANT
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Auxiliary Trip Coil Voltage Type and Rating in Volts18.0 DC NOMINAL SINGLE LOCATION
Actuator FunctionTRIP-RESET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
T14-S-SP-7413-1 5/2 Secondary reference
U.S. Government activity
2802961 3/9 Design control — primary reference
General Motors Corp Delco Products Div Machine Control Systems
AM-336 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-264-2751?

NSN 5925-01-264-2751 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-264-2751?

Key specifications for 5925-01-264-2751: Bushing Length: 0.458 INCHES MINIMUM AND 0.478 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES/RELAY TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 32.0 DC SINGLE LOCATION. 29 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-264-2751 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com