  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.099 INCHES MINIMUM AND 0.099 INCHES MINIMUM AND 0.161 INCHES MAXIMUM0.161 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 6 THREADED HOLE(S)6 THREADED HOLE(S)
  • Actuator Position Designation: AT EACH POLE
  • Switch Terminal Type: TAB, SOLDER LUG
Identification
  • NSN: 5925-01-261-9537
  • NIIN: 012619537
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-261-9537, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-261-9537
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.099 INCHES MINIMUM AND 0.099 INCHES MINIMUM AND 0.161 INCHES MAXIMUM0.161 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity6 THREADED HOLE(S)6 THREADED HOLE(S)
Actuator Position DesignationAT EACH POLE
Switch Terminal TypeTAB, SOLDER LUG
Frequency in Hertz400.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width1.629 INCHES MINIMUM AND 1.629 INCHES MINIMUM AND 1.691 INCHES MAXIMUM1.691 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGEDMODERATELY RUGGED
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPEMULTIPOLE-MULTIPLE ACTUATOR TYPE
Switch Voltage Rating and Type in Volts240.0 AC AND 50.0 DC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent150.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE, TWO, AND THREE LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length0.719 INCHES MINIMUM AND 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM0.781 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUTMAGNETIC BLOWOUT
Switch Location and Position DesignationINTERNAL AT POLE ONE
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.969 INCHES MINIMUM AND 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM2.031 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE
Pole Quantity33
Mounting Surface to Terminal End Distance2.032 INCHES MAXIMUM2.032 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole12.5 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 AC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Specification/standard Data81349-MIL-C-55629/12 GOVERNMENT SPECIFICATION
Body Length2.219 INCHES MINIMUM AND 2.219 INCHES MINIMUM AND 2.281 INCHES MAXIMUM2.281 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.150 MINIMUM AT 200 PCT AND 1.900 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity3 TOGGLE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-C-55629/12 5/9 Secondary reference
U.S. Government activity
M55629/12-090 2/2 Government specification standardization
U.S. Government activity
MIL-PRF-55629/12 4/1 Identification reference
U.S. Government activity

Frequently Asked Questions

What is NSN 5925-01-261-9537?

NSN 5925-01-261-9537 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-261-9537?

Key specifications for 5925-01-261-9537: Bushing Length: 0.099 INCHES MINIMUM AND 0.099 INCHES MINIMUM AND 0.161 INCHES MAXIMUM0.161 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-261-9537 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com