The Circuit Breaker, cataloged under National Stock Number 5925-01-259-3602, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Oakland Industries Ltd. Government technical data includes 29 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-259-3602 |
| Primary Part Number | 44-200-P10-SI-043.800-10 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Oakland Industries Ltd |
| Status | ACTIVE |
| Bushing Length | 6.5 MILLIMETERS NOMINAL6.5 MILLIMETERS NOMINAL MM |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 28.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING1 THREADED BUSHING |
| Actuator Position Designation | AT POLE ONE |
| Switch Terminal Type | QUICK DISCONNECT, MALE |
| Body Style | SINGLE POLE TYPESINGLE POLE TYPE |
| Switch Voltage Rating and Type in Volts | 28.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 140.0 SINGLE LOCATION |
| Switch Location and Position Designation | INTERNAL AT POLE ONE |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 15.8 MILLIMETERS NOMINAL15.8 MILLIMETERS NOMINAL MM |
| Criticality Code Justification | FEAT |
| Pole Quantity | 11 |
| Mounting Surface to Terminal End Distance | 43.5 MILLIMETERS NOMINAL43.5 MILLIMETERS NOMINAL MM |
| Maximum Continuous Load Current Rating Per Pole | 100.0 MILLIAMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 100.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.375 INCHES IN |
| Body Length | 19.8 MILLIMETERS NOMINAL19.8 MILLIMETERS NOMINAL MM |
| Trip Delay Time in Seconds Per Rated Continuous Current | 11.000 MINIMUM AT 200 PCT AND 60.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 PUSH-PULL |
| Switch Current Rating and Type in Amps | 3.0 DC |
| Inclosure Protection Type for Which Designed | GENERAL PURPOSE |
| Switch Contact Arrangement | SINGLE POLE, DOUBLE THROWSINGLE POLE, DOUBLE THROW |
| Thread Quantity Per Inch | 2727 |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | Y |
| Part Number | Manufacturer |
|---|---|
| 44-200-P10-SI-043.800-10 PRIMARY | Oakland Industries Ltd (USA) |
| Reference | Meaning |
|---|---|
| 216556-7 | 7/2 Vendor item drawing reference U.S. Government activity |
NSN 5925-01-259-3602 is a Circuit Breaker, manufactured by Oakland Industries Ltd, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-259-3602 has 1 manufacturer part number on file: 44-200-P10-SI-043.800-10 (Oakland Industries Ltd).
Key specifications for 44-200-P10-SI-043.800-10: Bushing Length: 6.5 MILLIMETERS NOMINAL6.5 MILLIMETERS NOMINAL MM; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 28.0 DC SINGLE LOCATION. 29 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.