The Circuit Breaker, cataloged under National Stock Number 5925-01-255-3079, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 7 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-255-3079 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Operating Voltage Type and Rating Per Pole in Volts | 50.0 DC SINGLE LOCATION |
| Pole Quantity | 11 |
| Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.500 MINIMUM AT 125 PCT AND 6.500 MAXIMUM AT 125 PCT AND 0.300 MINIMUM AT 150 PCT AND 3.000 MAXIMUM AT 150 PCT AND 0.130 MINIMUM AT 200 PCT AND 1.200 MAXIMUM AT 200 PCT AND 0.031 MINIMUM AT 400 PCT AND 0.220 MAXIMUM AT 400 PCT AND 0.031 MINIMUM AT 600 PCT AND 0.220 MAXIMUM AT 600 PCT AND 0.0110 MINIMUM AT 800 PCT AND 0.110 MAXIMUM AT 800 PCT AND 0.004 MINIMUM AT 1000 PCT AND 0.050 MAXIMUM AT 1000 PCT SINGLE LOCATION |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 911383-001 | 7/2 Vendor item drawing reference Moog Inc Div Moog Inc., Space and Defense - Salt Lake City |
| APL2-9433-1 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-255-3079 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-255-3079: Operating Voltage Type and Rating Per Pole in Volts: 50.0 DC SINGLE LOCATION; Pole Quantity: 11; Maximum Continuous Load Current Rating Per Pole: 20.0 AMPERES DC SINGLE LOCATION; Trip Release Characteristic: TIME DELAY SINGLE LOCATION. 7 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.