The Circuit Breaker, cataloged under National Stock Number 5925-01-254-8533, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Combat Capabilities Development Command (ccdc) Armaments Center Dba Ccdc Div Logistics Research and Engineering Directorate. Government technical data includes 29 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-254-8533 |
| Primary Part Number | 9291654-2 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Combat Capabilities Development Command (ccdc) Armaments Center Dba Ccdc Div Logistics Research and Engineering Directorate |
| Status | ACTIVE |
| Bushing Length | 0.344 INCHES MINIMUM AND 0.344 INCHES MINIMUM AND 0.406 INCHES MAXIMUM0.406 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 32.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING1 THREADED BUSHING |
| Actuator Position Designation | AT POLE ONE |
| Fragility Factor | MODERATELY RUGGEDMODERATELY RUGGED |
| Body Style | SINGLE POLE TYPESINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SINGLE LOCATION |
| Arc Quenching Method | MAGNETIC BLOWOUTMAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.719 INCHES MINIMUM AND 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM0.781 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 11 |
| Mounting Surface to Terminal End Distance | 2.094 INCHES MINIMUM AND 2.094 INCHES MINIMUM AND 2.156 INCHES MAXIMUM2.156 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.375 INCHES IN |
| Body Length | 1.969 INCHES MINIMUM AND 1.969 INCHES MINIMUM AND 2.031 INCHES MAXIMUM2.031 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.150 MINIMUM AT 200 PCT AND 1.400 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Inclosure Protection Type for Which Designed | DUSTPROOF |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 2 TAB W/SCREW |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Thread Series Designator | UNEF |
| Trip Release Method | MAGNETIC-HYDRAULIC SINGLE LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 9291654-2 | Combat Capabilities Development Command (ccdc) Armaments Center Dba Ccdc Div Logistics Research and Engineering Directorate (USA) |
| Reference | Meaning |
|---|---|
| JE1-V3-A-10-3 | 3/9 Design control — primary reference Eaton Corp Heinemann Products Commercial Controls Div |
NSN 5925-01-254-8533 is a Circuit Breaker, manufactured by Combat Capabilities Development Command (ccdc) Armaments Center Dba Ccdc Div Logistics Research and Engineering Directorate, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-254-8533 has 1 manufacturer part number on file: 9291654-2 (Combat Capabilities Development Command (ccdc) Armaments Center Dba Ccdc Div Logistics Research and Engineering Directorate).
Key specifications for 9291654-2: Bushing Length: 0.344 INCHES MINIMUM AND 0.344 INCHES MINIMUM AND 0.406 INCHES MAXIMUM0.406 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 32.0 DC SINGLE LOCATION. 29 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.