The Circuit Breaker, cataloged under National Stock Number 5925-01-252-6045, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Thales Uk Limited Dba Thales Uk Ltd Training and Simulation. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 2 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-252-6045 |
| Primary Part Number | 510046D |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Thales Uk Limited Dba Thales Uk Ltd Training and Simulation |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 THREADED HOLE(S)4 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Switch Terminal Type | TAB, SOLDER LUG |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.740 INCHES MINIMUM AND 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM0.760 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGEDMODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPEMULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Switch Voltage Rating and Type in Volts | 250.0 AC AND 30.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE AND TWO LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.052 INCHES MINIMUM AND 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM2.072 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUTMAGNETIC BLOWOUT |
| Switch Location and Position Designation | INTERNAL AT POLE ONE |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.490 INCHES MINIMUM AND 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM1.510 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 22 |
| Mounting Surface to Terminal End Distance | 2.461 INCHES MINIMUM AND 2.461 INCHES MINIMUM AND 2.481 INCHES MAXIMUM2.481 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC ALL LOCATIONS |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 2.490 INCHES MINIMUM AND 2.490 INCHES MINIMUM AND 2.510 INCHES MAXIMUM2.510 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.150 MINIMUM AT 200 PCT AND 1.500 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 2 TOGGLE |
| Switch Current Rating and Type in Amps | 10.0 AC AND 5.0 DC |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 0.740 INCHES MINIMUM AND 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM0.760 INCHES MAXIMUM IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 510046D | Thales Uk Limited Dba Thales Uk Ltd Training and Simulation (GBR) |
| 64510046D | Thales Uk Limited Dba Thales Uk Ltd Training and Simulation (GBR) |
| Reference | Meaning |
|---|---|
| AM2S-A2A3-LA-07-D-A-52-20-3 | 3/9 Design control — primary reference Eaton Corp Heinemann Products Commercial Controls Div |
NSN 5925-01-252-6045 is a Circuit Breaker, manufactured by Thales Uk Limited Dba Thales Uk Ltd Training and Simulation, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-252-6045 has 2 manufacturer part numbers on file: 510046D (Thales Uk Limited Dba Thales Uk Ltd Training and Simulation), 64510046D (Thales Uk Limited Dba Thales Uk Ltd Training and Simulation).
Key specifications for 510046D: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED HOLE(S)4 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.