PartsTable TECHNICAL DATA SHEET
NSN 5925-01-249-5285Government record, cited

Circuit Breaker5925-01-249-5285

NSN 5925-01-249-5285 · NIIN 012495285
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-249-5285 · 5925012495285 · NIIN 012495285 · 01-249-5285 · FSC 5925 Circuit Breakers · 2TC2-2 1/2 · 2TC2-2-5
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.040 INCHES MINIMUM AND 0.040 INCHES MINIMUM AND 0.055 INCHES MAXIMUM0.055 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 28.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING WITH PANEL SEAL1 THREADED BUSHING WITH PANEL SEAL
  • Actuator Position Designation: AT POLE ONE
  • Frequency in Hertz: 400.0 SINGLE LOCATION
Identification
  • NSN: 5925-01-249-5285
  • NIIN: 012495285
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-249-5285, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-249-5285
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.040 INCHES MINIMUM AND 0.040 INCHES MINIMUM AND 0.055 INCHES MAXIMUM0.055 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts120.0 AC AND 28.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity1 THREADED BUSHING WITH PANEL SEAL1 THREADED BUSHING WITH PANEL SEAL
Actuator Position DesignationAT POLE ONE
Frequency in Hertz400.0 SINGLE LOCATION
Fragility FactorMODERATELY RUGGEDMODERATELY RUGGED
Body StyleSINGLE POLE TYPESINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent138.0 SINGLE LOCATION
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.531 INCHES MINIMUM AND 0.531 INCHES MINIMUM AND 0.593 INCHES MAXIMUM0.593 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE
Pole Quantity11
Mounting Surface to Terminal End Distance1.281 INCHES MINIMUM AND 1.281 INCHES MINIMUM AND 1.343 INCHES MAXIMUM1.343 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole2.5 AMPERES AC AND 2.5 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2500.0 AC AND 6000.0 DC SINGLE LOCATION
Nominal Thread Size0.438 INCHES IN
Body Length0.719 INCHES MINIMUM AND 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM0.781 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current5.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 PUSH-PULL
Inclosure Protection Type for Which DesignedGENERAL PURPOSE
Thread Quantity Per Inch3232
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Terminal Type and Quantity2 TAB W/SCREW
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNS
Trip Release MethodTHERMAL SINGLE LOCATION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5925-01-586-65542TC2-25 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)Sensata Technologies, Inc. Div Sensata Attleboro
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
2TC2-2 1/2 3/2 Design control — primary reference
U.S. Government activity
2TC2-2-5 5/9 Secondary reference
U.S. Government activity
Related Parts
5925-01-586-6554POSSIBLE MATCH
CIRCUIT BREAKER
2TC2-25

Frequently Asked Questions

What is NSN 5925-01-249-5285?

NSN 5925-01-249-5285 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-249-5285?

1 possible match (shared part number, not a government interchangeability claim): 5925-01-586-6554. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-249-5285?

Key specifications for 5925-01-249-5285: Bushing Length: 0.040 INCHES MINIMUM AND 0.040 INCHES MINIMUM AND 0.055 INCHES MAXIMUM0.055 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 28.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-249-5285 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com