PartsTable TECHNICAL DATA SHEET
NSN 5925-01-248-5906Government record, cited

Circuit Breaker5925-01-248-5906

NSN 5925-01-248-5906 · NIIN 012485906 · Part number 10M10-1358
The Boeing Company Div Defense · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 76301
Government record, cited
NSN 5925-01-248-5906 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-248-5906. Manufacturer of record part number: 10M10-1358.
Also searched as  5925-01-248-5906 · 5925012485906 · NIIN 012485906 · 01-248-5906 · FSC 5925 Circuit Breakers · CAGE 76301 · 10M10-1358 · 3XAM1516MG3-10-250-1-60
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 6 THREADED HOLE(S)6 THREADED HOLE(S)
  • Actuator Position Designation: AT EACH POLE
  • Frequency in Hertz: 60.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 1.021 INCHES MINIMUM AND 1.021 INCHES MINIMUM AND 1.041 INCHES MAXIMUM1.041 INCHES MAXIMUM IN
Identification
  • NSN: 5925-01-248-5906
  • NIIN: 012485906
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: 10M10-1358
  • Manufacturer: The Boeing Company Div Defense
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-248-5906, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is The Boeing Company Div Defense. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-248-5906
Primary Part Number10M10-1358
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerThe Boeing Company Div Defense
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts250.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity6 THREADED HOLE(S)6 THREADED HOLE(S)
Actuator Position DesignationAT EACH POLE
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width1.021 INCHES MINIMUM AND 1.021 INCHES MINIMUM AND 1.041 INCHES MAXIMUM1.041 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGEDMODERATELY RUGGED
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPEMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE, TWO, AND THREE LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.740 INCHES MINIMUM AND 2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM2.760 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUTMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width3.042 INCHES MINIMUM AND 3.042 INCHES MINIMUM AND 3.062 INCHES MAXIMUM3.062 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSEGENERAL PURPOSE WAREHOUSE
Pole Quantity33
Mounting Surface to Terminal End Distance3.239 INCHES NOMINAL3.239 INCHES NOMINAL IN
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1500.0 AC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Body Length3.709 INCHES MINIMUM AND 3.709 INCHES MINIMUM AND 3.729 INCHES MAXIMUM3.729 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current25.000 MINIMUM AT 200 PCT AND 105.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity3 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width1.021 INCHES MINIMUM AND 1.021 INCHES MINIMUM AND 1.041 INCHES MAXIMUM1.041 INCHES MAXIMUM IN
Inclosure Protection Type for Which DesignedDUSTPROOF AND FUNGUS PROOF
Thread Quantity Per Inch3232
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
10M10-1358 PRIMARY The Boeing Company Div Defense (USA)
Reference documents
ReferenceMeaning
3XAM1516MG3-10-250-1-60 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-248-5906?

NSN 5925-01-248-5906 is a Circuit Breaker, manufactured by The Boeing Company Div Defense, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-01-248-5906?

NSN 5925-01-248-5906 has 1 manufacturer part number on file: 10M10-1358 (The Boeing Company Div Defense).

What are the specifications of 10M10-1358?

Key specifications for 10M10-1358: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 6 THREADED HOLE(S)6 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-248-5906 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.