PartsTable TECHNICAL DATA SHEET
NSN 5925-01-244-8950Government record, cited

Circuit Breaker5925-01-244-8950

NSN 5925-01-244-8950 · NIIN 012448950
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-244-8950 · 5925012448950 · NIIN 012448950 · 01-244-8950 · FSC 5925 Circuit Breakers · 46-056896-01 · AP-112-1-42F-252 · AP112-1-42F-252 · 46-056896-01
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.380 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING WITH PANEL SEAL
  • Actuator Position Designation: AT POLE TWO
  • Frequency in Hertz: 400.0 ALL LOCATIONS
Identification
  • NSN: 5925-01-244-8950
  • NIIN: 012448950
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-244-8950, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-244-8950
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.380 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts240.0 AC AND 50.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity1 THREADED BUSHING WITH PANEL SEAL
Actuator Position DesignationAT POLE TWO
Frequency in Hertz400.0 ALL LOCATIONS
Unpackaged Unit Weight5.400 OUNCES NOMINAL OZ
Center to Center Distance Between Terminals Parallel to Width0.615 INCHES MINIMUM AND 0.635 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent150.0 ALL LOCATIONS
Arc Quenching MethodMAGNETIC BLOWOUT
Nonturn Device Length0.005 INCHES MINIMUM AND 0.015 INCHES MAXIMUM IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.875 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity3
Mounting Surface to Terminal End Distance1.780 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole2.5 AMPERES AC AND 2.5 AMPERES DC ALL LOCATIONS
Features ProvidedHIGH INRUSH PROTECTION
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps300.0 AC AND 500.0 DC ALL LOCATIONS
Nominal Thread Size0.375 INCHES IN
Body Length1.500 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedHERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT
Nonturn Device Diameter0.250 INCHES NOMINAL IN
Thread Quantity Per Inch32
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
46-056896-01 C/1 Advisory reference — outside the item-of-supply concept
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Multiple
AP-112-1-42F-252 5/9 Secondary reference
U.S. Government activity
AP112-1-42F-252 3/2 Design control — primary reference
U.S. Government activity
46-056896-01 3/9 Design control — primary reference
Northrop Grumman Systems Corporation Div Es Defensive Systems Division

Frequently Asked Questions

What is NSN 5925-01-244-8950?

NSN 5925-01-244-8950 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-244-8950?

Key specifications for 5925-01-244-8950: Bushing Length: 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-244-8950 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com