The Circuit Breaker, cataloged under National Stock Number 5925-01-243-3771, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 28 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-243-3771 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Operating Voltage Type and Rating Per Pole in Volts | 600.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 4 UNTHREADED HOLE(S) |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Unpackaged Unit Weight | 3.800 POUNDS NOMINAL LBS |
| Center to Center Distance Between Terminals Parallel to Width | 1.125 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 4.000 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 3.000 INCHES NOMINAL IN |
| Body Height | 4.000 INCHES NOMINAL IN |
| Unthreaded Mounting Hole Diameter | 0.187 INCHES NOMINAL IN |
| Trip Release Duty Cycle | INTERMITTENT ALL LOCATIONS |
| Pole Quantity | 3 |
| Maximum Continuous Load Current Rating Per Pole | 80.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 80.0 AC ALL LOCATIONS |
| Body Length | 6.328 INCHES NOMINAL IN |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 1.250 INCHES NOMINAL IN |
| Cubic Measure | 0.040 CUBIC FEET |
| Material | PLASTIC CASE |
| Trip Release Ambient Temp Rating | 50.0 CELSIUS NOMINAL ALL LOCATIONS DEGC |
| Terminal Type and Quantity | 6 COMPRESSION |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Boss Height | 0.250 INCHES NOMINAL IN |
| Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Length | 5.250 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| E43M080 | 3/9 Design control — primary reference Siemens Energy and Automation Inc Ite Electrical Apparatus Div |
NSN 5925-01-243-3771 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-243-3771: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 600.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S); Frequency in Hertz: 60.0 ALL LOCATIONS. 28 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.