The Circuit Breaker, cataloged under National Stock Number 5925-01-241-4590, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp. Government technical data includes 23 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-241-4590 |
| Primary Part Number | 900486-0515 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp |
| Status | ACTIVE |
| Bushing Length | 0.344 INCHES MINIMUM AND 0.375 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC ALL LOCATIONS |
| Ultimate Trip Time Per Pole in Seconds | 40.000 NOMINAL ALL LOCATIONS |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.906 INCHES MINIMUM AND 1.937 INCHES MAXIMUM IN |
| Pole Quantity | 3 |
| Mounting Surface to Terminal End Distance | 1.797 INCHES MINIMUM AND 1.828 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 2.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 300.0 AC ALL LOCATIONS |
| Body Length | 1.531 INCHES MINIMUM AND 1.562 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 1.000 MINIMUM AT 200 PCT AND 3.700 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 6 TOGGLE |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 2 WIRE HOOK |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Trip Release Method | MAGNETIC ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Length | 0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 900486-0515 PRIMARY | Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp (USA) |
NSN 5925-01-241-4590 is a Circuit Breaker, manufactured by Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-241-4590 has 1 manufacturer part number on file: 900486-0515 (Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp).
Key specifications for 900486-0515: Bushing Length: 0.344 INCHES MINIMUM AND 0.375 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS. 23 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.