PartsTable TECHNICAL DATA SHEET
NSN 5925-01-239-2040Government record, cited

Circuit Breaker5925-01-239-2040

NSN 5925-01-239-2040 · NIIN 012392040 · Part number CE2--G3-U-0030-01A
Eaton Corp Aerospace Commercial Controls Div · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 1W134
Government record, cited
NSN 5925-01-239-2040 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-239-2040. Manufacturer of record part number: CE2--G3-U-0030-01A.
Also searched as  5925-01-239-2040 · 5925012392040 · NIIN 012392040 · 01-239-2040 · FSC 5925 Circuit Breakers · CAGE 1W134 · CE2--G3-U-0030-01A · 016367-2 · 845001A0062-2 · 845001A0062-2 · 209-2-1-63-3-1-30
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 THREADED HOLE(S) AND 4 SLOT
  • Actuator Position Designation: AT EACH POLE
  • Frequency in Hertz: 50.0 OR 60.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 1.032 INCHES NOMINAL IN
Identification
  • NSN: 5925-01-239-2040
  • NIIN: 012392040
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: CE2--G3-U-0030-01A
  • Manufacturer: Eaton Corp Aerospace Commercial Controls Div
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-239-2040, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Eaton Corp Aerospace Commercial Controls Div. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-239-2040
Primary Part NumberCE2--G3-U-0030-01A
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerEaton Corp Aerospace Commercial Controls Div
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity4 THREADED HOLE(S) AND 4 SLOT
Actuator Position DesignationAT EACH POLE
Frequency in Hertz50.0 OR 60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width1.032 INCHES NOMINAL IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE AND TWO LINKED
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.750 INCHES NOMINAL IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width2.064 INCHES NOMINAL IN
Body Height2.609 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity2
Maximum Continuous Load Current Rating Per Pole30.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC ALL LOCATIONS
Nominal Thread Size0.138 INCHES IN
Body Length5.844 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current20.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity2 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width1.032 INCHES NOMINAL IN
Inclosure Protection Type for Which DesignedDUSTPROOF
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
CE2--G3-U-0030-01A Eaton Corp Aerospace Commercial Controls Div (USA)
Reference documents
ReferenceMeaning
016367-2 5/9 Secondary reference
Ikon Systems Inc
845001A0062-2 7/2 Vendor item drawing reference
Marine Corps Systems Command Div Marine Corps Systems Command Technical Data Repository Customer Service
845001A0062-2 5/9 Secondary reference
U.S. Government activity
209-2-1-63-3-1-30 3/2 Design control — primary reference
U.S. Government activity
CE2-G3-U-30-120/240-1 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-239-2040?

NSN 5925-01-239-2040 is a Circuit Breaker, manufactured by Eaton Corp Aerospace Commercial Controls Div, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-01-239-2040?

NSN 5925-01-239-2040 has 1 manufacturer part number on file: CE2--G3-U-0030-01A (Eaton Corp Aerospace Commercial Controls Div).

What are the specifications of CE2--G3-U-0030-01A?

Key specifications for CE2--G3-U-0030-01A: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED HOLE(S) AND 4 SLOT. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-239-2040 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com