The Circuit Breaker, cataloged under National Stock Number 5925-01-237-8734, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-237-8734 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Bushing Length | 0.380 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP FIRST LOCATION |
| Internal Trip Release Configuration | RELAY TRIP SECOND LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC AND 50.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL |
| Actuator Position Designation | BETWEEN POLE ONE AND TWO |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.625 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 115.0 ALL LOCATIONS |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.281 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 1.828 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 2.0 AMPERES AC AND 5.0 MILLIAMPERES DC ALL LOCATIONS |
| Features Provided | HIGH INRUSH PROTECTION |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 300.0 AC AND 500.0 DC ALL LOCATIONS |
| Nominal Thread Size | 0.375 INCHES IN |
| Body Length | 1.562 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.035 MAXIMUM AT 150 PCT AND 0.025 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Inclosure Protection Type for Which Designed | HERMETICALLY SEALED |
| Thread Quantity Per Inch | 32 |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 4 WIRE HOOK AND 2 TAB, SOLDER LUG |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Thread Series Designator | UNEF |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| AP14-21221-1 | 3/2 Design control — primary reference U.S. Government activity |
| 29-1345229-1 | 5/9 Secondary reference Gte Government Systems Corp Strategic Systems Div |
NSN 5925-01-237-8734 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-237-8734: Bushing Length: 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION; Internal Trip Release Configuration: RELAY TRIP SECOND LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.