PartsTable TECHNICAL DATA SHEET
NSN 5925-01-236-1018Government record, cited

Circuit Breaker5925-01-236-1018

NSN 5925-01-236-1018 · NIIN 012361018
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-236-1018 · 5925012361018 · NIIN 012361018 · 01-236-1018 · FSC 5925 Circuit Breakers · UPL-1-1RO-64F-203M · 0N333873-3
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Switch Terminal Type: SOLDER STUD
  • Frequency in Hertz: 50.0 OR 60.0 SINGLE LOCATION
Identification
  • NSN: 5925-01-236-1018
  • NIIN: 012361018
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-236-1018, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-236-1018
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts250.0 AC SINGLE LOCATION
Mounting Facility Type and Quantity2 THREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Switch Terminal TypeSOLDER STUD
Frequency in Hertz50.0 OR 60.0 SINGLE LOCATION
Unpackaged Unit Weight3.700 OUNCES NOMINAL OZ
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Switch Voltage Rating and Type in Volts250.0 AC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM IN
Arc Quenching MethodMAGNETIC BLOWOUT
Switch Location and Position DesignationINTERNAL AT POLE ONE
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.750 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance2.490 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole20.0 AMPERES AC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Body Length2.480 INCHES MINIMUM AND 2.500 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.150 MINIMUM AT 200 PCT AND 1.500 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Switch Current Rating and Type in Amps10.0 AC
Inclosure Protection Type for Which DesignedMOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
UPL-1-1RO-64F-203M 5/2 Secondary reference
U.S. Government activity
0N333873-3 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-236-1018?

NSN 5925-01-236-1018 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-236-1018?

Key specifications for 5925-01-236-1018: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED HOLE(S). 29 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-236-1018 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com