The Circuit Breaker, cataloged under National Stock Number 5925-01-229-8654, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Heinemann Electric Canada Incdivision of Eaton Corp. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-229-8654 |
| Primary Part Number | CD2-Z-406-1 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Heinemann Electric Canada Incdivision of Eaton Corp |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP FIRST LOCATION |
| Internal Trip Release Configuration | RELAY TRIP SECOND LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC FIRST LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 115.0 AC SECOND LOCATION |
| Mounting Facility Type and Quantity | 4 THREADED HOLE(S) AND 4 SLOT |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 50.0 OR 60.0 ALL LOCATIONS |
| Unpackaged Unit Weight | 1.188 POUNDS NOMINAL LBS |
| Center to Center Distance Between Terminals Parallel to Width | 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE AND TWO LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.718 INCHES MINIMUM AND 2.782 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 2.038 INCHES MINIMUM AND 2.102 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 3.172 INCHES MINIMUM AND 3.296 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 85.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | INSTANTANEOUS SECOND LOCATION |
| Trip Release Characteristic | TIME DELAY FIRST LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 5000.0 AC ALL LOCATIONS |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 5.768 INCHES MINIMUM AND 5.832 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 35.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT FIRST LOCATION |
| Manual Actuator Type and Quantity | 2 TOGGLE |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| CD2-Z-406-1 | Heinemann Electric Canada Incdivision of Eaton Corp (CAN) |
| Reference | Meaning |
|---|---|
| CD2-A3A6-85-240-1-11 | C/1 Advisory reference — outside the item-of-supply concept Eaton Corp Heinemann Products Commercial Controls Div |
| CD2A3A9UP185A240AC12 | C/1 Advisory reference — outside the item-of-supply concept Eaton Corp Heinemann Products Commercial Controls Div |
| WT-C0078-001 | C/1 Advisory reference — outside the item-of-supply concept Raytheon E-Systems, Inc |
| CD2A3A6U-P1-85A240AC1-P2-115AC-P | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
| CD2-Z-406-1 | 3/9 Design control — primary reference Eaton Corp Heinemann Products Commercial Controls Div |
NSN 5925-01-229-8654 is a Circuit Breaker, manufactured by Heinemann Electric Canada Incdivision of Eaton Corp, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-229-8654 has 1 manufacturer part number on file: CD2-Z-406-1 (Heinemann Electric Canada Incdivision of Eaton Corp).
Key specifications for CD2-Z-406-1: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION; Internal Trip Release Configuration: RELAY TRIP SECOND LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC FIRST LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.