PartsTable TECHNICAL DATA SHEET
NSN 5925-01-219-7225Government record, cited

Circuit Breaker5925-01-219-7225

NSN 5925-01-219-7225 · NIIN 012197225
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-219-7225 · 5925012197225 · NIIN 012197225 · 01-219-7225 · FSC 5925 Circuit Breakers · FB2100-50C · FB2100-50C
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Fragility Factor: MODERATELY RUGGED
  • Body Style: SINGLE POLE TYPE
  • Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 125.0 SINGLE LOCATION
  • Distance Between Centerlines of Mounting Facilities Parallel to Body Length: 5.188 INCHES NOMINAL IN
Identification
  • NSN: 5925-01-219-7225
  • NIIN: 012197225
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-219-7225, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 26 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-219-7225
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Mounting Facility Type and Quantity2 UNTHREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length5.188 INCHES NOMINAL IN
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width1.375 INCHES NOMINAL IN
Body Height3.375 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.188 INCHES NOMINAL IN
Pole Quantity1
Body Length6.000 INCHES NOMINAL IN
Manual Actuator Type and Quantity1 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width1.000 INCHES NOMINAL IN
Inclosure Protection Type for Which DesignedDUSTPROOF
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating40.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Terminal Type and Quantity2 COMPRESSION
Main Contact Tripping Mechanism TypeTRIP FREE
Boss Height0.125 INCHES NOMINAL IN
Trip Release MethodTHERMAL-MAGNETIC SINGLE LOCATION
Center to Center Distance Between Terminals Parallel to Length5.062 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
FB2100-50C 3/9 Design control — primary reference
Westinghouse Electric Corp Control Business Unit
FB2100-50C C/1 Advisory reference — outside the item-of-supply concept
Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-219-7225?

NSN 5925-01-219-7225 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-219-7225?

Key specifications for 5925-01-219-7225: Reset Method: MANUAL; Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S); Actuator Position Designation: AT POLE ONE; Fragility Factor: MODERATELY RUGGED. 26 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-219-7225 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com