The Circuit Breaker, cataloged under National Stock Number 5925-01-216-1977, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-216-1977 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Bushing Length | 0.332 INCHES MINIMUM AND 0.375 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SECOND LOCATION |
| Internal Trip Release Configuration | SERIES TRIP THIRD LOCATION |
| Internal Trip Release Configuration | RELAY TRIP FIRST LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC SECOND LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 115.0 AC FIRST LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC THIRD LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL |
| Actuator Position Designation | AT POLE TWO |
| Switch Terminal Type | TAB, SOLDER LUG |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM IN |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Switch Voltage Rating and Type in Volts | 125.0 AC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 115.0 ALL LOCATIONS |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Switch Location and Position Designation | INTERNAL AT POLE THREE |
| Circuit Protection Type | OVERCURRENT THIRD LOCATION |
| Circuit Protection Type | OVERCURRENT SECOND LOCATION |
| Circuit Protection Type | OVERVOLTAGE FIRST LOCATION |
| Body Width | 1.875 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 3 |
| Mounting Surface to Terminal End Distance | 1.780 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC SECOND LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC THIRD LOCATION |
| Trip Release Characteristic | INSTANTANEOUS FIRST LOCATION |
| Trip Release Characteristic | TIME DELAY THIRD LOCATION |
| Trip Release Characteristic | TIME DELAY SECOND LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| AP411-1R5329-6 | 5/2 Secondary reference U.S. Government activity |
| 29-1217615-6 | 3/9 Design control — primary reference General Dynamics Advanced Information Systems Inc. Dba General Dynamics Advanced Information Systems |
NSN 5925-01-216-1977 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-216-1977: Bushing Length: 0.332 INCHES MINIMUM AND 0.375 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION; Internal Trip Release Configuration: SERIES TRIP THIRD LOCATION. 30 specifications are documented in the U.S. Government catalog.