The Circuit Breaker, cataloged under National Stock Number 5925-01-210-7198, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 23 specifications, cited from the U.S. Government catalog. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-210-7198 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | AUTOMATIC |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 110.0 AC AND 30.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 2 UNTHREADED HOLE(S) |
| Frequency in Hertz | 400.0 SINGLE LOCATION |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 130.0 SINGLE LOCATION |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.406 INCHES NOMINAL IN |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 1.875 INCHES NOMINAL IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Unthreaded Mounting Hole Diameter | 0.250 INCHES NOMINAL IN |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 1.032 INCHES NOMINAL IN |
| Maximum Continuous Load Current Rating Per Pole | 70.0 AMPERES AC AND 70.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 875.0 AC AND 875.0 DC SINGLE LOCATION |
| Trip Delay Time in Seconds Per Rated Continuous Current | 6.000 MINIMUM AT 200 PCT AND 60.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Inclosure Protection Type for Which Designed | SHOCKPROOF AND VIBRATIONPROOF |
| Trip Release Ambient Temp Rating | 77.0 FAHRENHEIT NOMINAL SINGLE LOCATION DEGF |
| Terminal Type and Quantity | 2 SCREW |
| Trip Release Method | THERMAL SINGLE LOCATION |
| Center to Center Distance Between Terminals Parallel to Length | 1.062 INCHES NOMINAL IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| CLA-70 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-210-7198 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-210-7198: Reset Method: AUTOMATIC; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 110.0 AC AND 30.0 DC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S). 23 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.