PartsTable TECHNICAL DATA SHEET
NSN 5925-01-209-1762Government record, cited

Circuit Breaker5925-01-209-1762

NSN 5925-01-209-1762 · NIIN 012091762
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-209-1762 · 5925012091762 · NIIN 012091762 · 01-209-1762 · FSC 5925 Circuit Breakers · 29-1217615-5 · AP411-5329-5
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.332 INCHES MINIMUM AND 0.375 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION
  • Internal Trip Release Configuration: SERIES TRIP THIRD LOCATION
  • Internal Trip Release Configuration: RELAY TRIP FIRST LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC SECOND LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 115.0 AC FIRST LOCATION
Identification
  • NSN: 5925-01-209-1762
  • NIIN: 012091762
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-209-1762, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-209-1762
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.332 INCHES MINIMUM AND 0.375 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SECOND LOCATION
Internal Trip Release ConfigurationSERIES TRIP THIRD LOCATION
Internal Trip Release ConfigurationRELAY TRIP FIRST LOCATION
Operating Voltage Type and Rating Per Pole in Volts240.0 AC SECOND LOCATION
Operating Voltage Type and Rating Per Pole in Volts115.0 AC FIRST LOCATION
Operating Voltage Type and Rating Per Pole in Volts240.0 AC THIRD LOCATION
Mounting Facility Type and Quantity1 THREADED BUSHING WITH PANEL SEAL
Actuator Position DesignationAT POLE TWO
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.595 INCHES MINIMUM AND 0.656 INCHES MAXIMUM IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent115.0 ALL LOCATIONS
Circuit Protection TypeOVERCURRENT THIRD LOCATION
Circuit Protection TypeOVERCURRENT SECOND LOCATION
Circuit Protection TypeOVERVOLTAGE FIRST LOCATION
Body Width1.875 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity3
Mounting Surface to Terminal End Distance1.780 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole5.0 AMPERES AC SECOND LOCATION
Maximum Continuous Load Current Rating Per Pole5.0 AMPERES AC THIRD LOCATION
Trip Release CharacteristicINSTANTANEOUS FIRST LOCATION
Trip Release CharacteristicTIME DELAY THIRD LOCATION
Trip Release CharacteristicTIME DELAY SECOND LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps300.0 AC ALL LOCATIONS
Nominal Thread Size0.375 INCHES IN
Body Length1.500 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT SECOND LOCATION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
29-1217615-5 3/9 Design control — primary reference
General Dynamics Advanced Information Systems Inc. Dba General Dynamics Advanced Information Systems
AP411-5329-5 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-209-1762?

NSN 5925-01-209-1762 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-209-1762?

Key specifications for 5925-01-209-1762: Bushing Length: 0.332 INCHES MINIMUM AND 0.375 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION; Internal Trip Release Configuration: SERIES TRIP THIRD LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-209-1762 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com