The Circuit Breaker, cataloged under National Stock Number 5925-01-194-3025, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Oakland Industries Ltd. Government technical data includes 28 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 4 commercial cross-references from 2 manufacturers, enabling identification through both NSN and commercial part number lookups. 3 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-194-3025 |
| Primary Part Number | 45-700-IG1-P10-DD-1.5A |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — No Item Name Available |
| Manufacturer | Oakland Industries Ltd |
| Status | ACTIVE |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 1.5 AMPERES AC AND 1.5 AMPERES DC SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 250.0 AC AND 28.0 DC SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 15.0 AC AND 15.0 DC SINGLE LOCATION |
| Trip Delay Time in Seconds Per Rated Continuous Current | 10.000 MINIMUM AT 200 PCT AND 40.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Trip Release Ambient Temp Rating | 70.0 FAHRENHEIT NOMINAL SINGLE LOCATION DEGF |
| Reset Method | MANUAL |
| Actuator Position Designation | AT POLE ONE |
| Manual Actuator Type and Quantity | 1 PUSH BUTTON |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 150.0 SINGLE LOCATION |
| Material | PLASTIC CASE |
| Terminal Type and Quantity | 2 QUICK DISCONNECT, MALE |
| Trip Release Method | THERMAL-MAGNETIC SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Bushing Length | 0.400 INCHES NOMINAL IN |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING |
| Thread Quantity Per Inch | 32 |
| Center to Center Distance Between Terminals Parallel to Length | 0.980 INCHES NOMINAL IN |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 2.260 INCHES NOMINAL IN |
| Body Style | SINGLE POLE TYPE |
| Body Length | 1.140 INCHES NOMINAL IN |
| Frequency in Hertz | 400.0 SINGLE LOCATION |
| Body Width | 0.570 INCHES NOMINAL IN |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Nominal Thread Size | 0.138 INCHES IN |
| Actuator Function | TRIP-RESET |
| Thread Series Designator | UNIFIED NATIONAL COARSE (UNC) |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 45-700-IG1-P10-DD-1.5A PRIMARY | Oakland Industries Ltd (USA) |
| 45-700-P10-DD-1.5A | Oakland Industries Ltd (USA) |
| 510016 | Gandalf Systems Corp (USA) |
| ETA-45-700-P-DD-1.5A | Oakland Industries Ltd (USA) |
NSN 5925-01-194-3025 is a Circuit Breaker, manufactured by Oakland Industries Ltd, classified under FSC 5925 (No Item Name Available). Status: active.
NSN 5925-01-194-3025 has 4 cross-referenced part numbers: 45-700-IG1-P10-DD-1.5A (Oakland Industries Ltd), 45-700-P10-DD-1.5A (Oakland Industries Ltd), 510016 (Gandalf Systems Corp), ETA-45-700-P-DD-1.5A (Oakland Industries Ltd).
There are 3 known substitutes for 5925-01-194-3025: 5310-00-118-6308, 5331-01-036-0916, 5306-01-128-1047. Verify interchangeability with system specifications before substitution.
Key specifications for 45-700-IG1-P10-DD-1.5A: Trip Release Characteristic: TIME DELAY SINGLE LOCATION; Maximum Continuous Load Current Rating Per Pole: 1.5 AMPERES AC AND 1.5 AMPERES DC SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 250.0 AC AND 28.0 DC SINGLE LOCATION; Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps: 15.0 AC AND 15.0 DC SINGLE LOCATION. 28 total characteristics are documented in the Federal Logistics Information System.