Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.235 INCHES MINIMUM AND 0.250 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 230.0 AC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Frequency in Hertz: 400.0 SINGLE LOCATION
Identification
  • NSN: 5925-01-192-7255
  • NIIN: 011927255
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-192-7255, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 5 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-192-7255
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.235 INCHES MINIMUM AND 0.250 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts230.0 AC SINGLE LOCATION
Mounting Facility Type and Quantity2 THREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Frequency in Hertz400.0 SINGLE LOCATION
Unpackaged Unit Weight0.230 POUNDS NOMINAL LBS
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent138.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length1.800 INCHES MINIMUM AND 1.820 INCHES MAXIMUM IN
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.760 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance2.370 INCHES NOMINAL IN
Maximum Continuous Load Current Rating Per Pole4.0 AMPERES AC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps5000.0 AC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Body Length2.189 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current10.000 MINIMUM AT 200 PCT AND 37.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 PUSH-PULL
Inclosure Protection Type for Which DesignedEXPLOSION PROOF AND HUMIDITY PROOF AND CORROSION RESISTANT AND DUSTPROOF AND SANDTIGHT AND FUNGUS RESISTANT
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Terminal Type and Quantity2 TAB W/SCREW
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
454-0105-026 5/2 Secondary reference
U.S. Government activity
6752-37-4 3/2 Design control — primary reference
U.S. Government activity
6752-34-4 5/9 Secondary reference
U.S. Government activity
454-0104-002 C/1 Advisory reference — outside the item-of-supply concept
U.S. Government activity
L454C2001-3-026 5/2 Secondary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-192-7255?

NSN 5925-01-192-7255 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-192-7255?

Key specifications for 5925-01-192-7255: Bushing Length: 0.235 INCHES MINIMUM AND 0.250 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 230.0 AC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-192-7255 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com