The Circuit Breaker, cataloged under National Stock Number 5925-01-189-9252, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Thales Nederland. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-189-9252 |
| Primary Part Number | 352250042488 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Thales Nederland |
| Status | ACTIVE |
| Bushing Length | 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC AND 50.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL |
| Actuator Position Designation | BETWEEN POLE ONE AND TWO |
| Switch Terminal Type | TAB, SOLDER LUG |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Unpackaged Unit Weight | 100.0 GRAMS NOMINAL G |
| Center to Center Distance Between Terminals Parallel to Width | 0.594 INCHES MINIMUM AND 0.656 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Switch Voltage Rating and Type in Volts | 120.0 AC AND 50.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Switch Location and Position Designation | INTERNAL AT POLE TWO |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.250 INCHES MINIMUM AND 1.281 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 1.797 INCHES MINIMUM AND 1.828 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 7.0 AMPERES AC AND 7.0 AMPERES DC ALL LOCATIONS |
| Features Provided | HIGH INRUSH PROTECTION |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 300.0 AC AND 500.0 DC ALL LOCATIONS |
| Nominal Thread Size | 0.375 INCHES IN |
| Specification/standard Data | 81349-MIL-C-39019/4 GOVERNMENT SPECIFICATION |
| Body Length | 1.531 INCHES MINIMUM AND 1.562 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Switch Current Rating and Type in Amps | 0.5 AC AND 0.5 DC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 352250042488 | Thales Nederland (NLD) |
| Reference | Meaning |
|---|---|
| MIL-PRF-39019/4 | 4/1 Identification reference U.S. Government activity |
| M39019/04-325 | 2/2 Government specification standardization U.S. Government activity |
| M39019/4-325 | C/1 Advisory reference — outside the item-of-supply concept U.S. Government activity |
| MIL-C-39019/4 | 5/9 Secondary reference U.S. Government activity |
NSN 5925-01-189-9252 is a Circuit Breaker, manufactured by Thales Nederland, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-189-9252 has 1 manufacturer part number on file: 352250042488 (Thales Nederland).
Key specifications for 352250042488: Bushing Length: 0.332 INCHES MINIMUM AND 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.