PartsTable TECHNICAL DATA SHEET
NSN 5925-01-176-5048Government record, cited

Circuit Breaker5925-01-176-5048

NSN 5925-01-176-5048 · NIIN 011765048
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-176-5048 · 5925011765048 · NIIN 011765048 · 01-176-5048 · FSC 5925 Circuit Breakers · 203-1-1-63-153-1-1 · TX1-P15-U00-WH2
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 125.0 AC AND 32.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 2 CLIP
  • Actuator Position Designation: AT POLE ONE
  • Frequency in Hertz: 60.0 SINGLE LOCATION
  • Fragility Factor: MODERATELY RUGGED
Identification
  • NSN: 5925-01-176-5048
  • NIIN: 011765048
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-176-5048, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 29 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-176-5048
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts125.0 AC AND 32.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity2 CLIP
Actuator Position DesignationAT POLE ONE
Frequency in Hertz60.0 SINGLE LOCATION
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent140.0 SINGLE LOCATION
Arc Quenching MethodMAGNETIC BLOWOUT
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.700 INCHES NOMINAL IN
Body Height1.630 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES AC AND 15.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps3500.0 AC AND 1000.0 DC SINGLE LOCATION
Body Length1.780 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current6.000 MINIMUM AT 200 PCT AND 41.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedGENERAL PURPOSE
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating40.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Terminal Type and Quantity2 TAB, SOLDER LUG
Special Handling FeatureMAGNETIC
Main Contact Tripping Mechanism TypeTRIP FREE
Boss Height0.320 INCHES NOMINAL IN
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5925-01-298-6311TX1P15U00WH2 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)U S Dept of Transportation Federal Aviation Administration
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
203-1-1-63-153-1-1 3/2 Design control — primary reference
U.S. Government activity
TX1-P15-U00-WH2 5/9 Secondary reference
Eaton Corp Heinemann Products Commercial Controls Div
Related Parts
5925-01-298-6311POSSIBLE MATCH
CIRCUIT BREAKER
TX1P15U00WH2

Frequently Asked Questions

What is NSN 5925-01-176-5048?

NSN 5925-01-176-5048 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-176-5048?

1 possible match (shared part number, not a government interchangeability claim): 5925-01-298-6311. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-176-5048?

Key specifications for 5925-01-176-5048: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 125.0 AC AND 32.0 DC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 CLIP. 29 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-176-5048 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com