PartsTable TECHNICAL DATA SHEET
NSN 5925-01-173-1114Government record, cited

Circuit Breaker5925-01-173-1114

NSN 5925-01-173-1114 · NIIN 011731114
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-173-1114 · 5925011731114 · NIIN 011731114 · 01-173-1114 · FSC 5925 Circuit Breakers · 313C682G18 · 313C682G18 · 313C682G18
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 500.0 AC AND 250.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE TWO
  • Frequency in Hertz: 400.0 ALL LOCATIONS
  • Center to Center Distance Between Terminals Parallel to Width: 3.000 INCHES NOMINAL IN
  • Body Style: MULTIPOLE-SINGLE ACTUATOR TYPE
Identification
  • NSN: 5925-01-173-1114
  • NIIN: 011731114
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-173-1114, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-173-1114
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts500.0 AC AND 250.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity4 THREADED HOLE(S)
Actuator Position DesignationAT POLE TWO
Frequency in Hertz400.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width3.000 INCHES NOMINAL IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent138.0 ALL LOCATIONS
Adjustable Trip Setting Current Range Per Pole in Amps+650.0 TO 1300.0 AC AND +650.0 TO 1300.0 DC ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length9.875 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width9.000 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity3
Mounting Surface to Terminal End Distance9.312 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole125.0 AMPERES AC AND 125.0 AMPERES DC ALL LOCATIONS
Features ProvidedADJUSTABLE TRIP RELEASE
Trip Release CharacteristicINSTANTANEOUS ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps10000.0 AC AND 15000.0 DC ALL LOCATIONS
Nominal Thread Size0.250 INCHES IN
Body Length11.000 INCHES MAXIMUM IN
Manual Actuator Type and Quantity1 TOGGLE
Distance Between Centerlines of Mounting Facilities Parallel to Body Width3.000 INCHES NOMINAL IN
Inclosure Protection Type for Which DesignedGENERAL PURPOSE
Thread Quantity Per Inch20
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating50.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Terminal Type and Quantity6 THREADED STUD
Main Contact Tripping Mechanism TypeTRIP FREE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
313C682G18 5/9 Secondary reference
Westinghouse Electric Corp Control Business Unit
313C682G18 C/1 Advisory reference — outside the item-of-supply concept
Westinghouse Electric Corp Power Generation-Generator Div
313C682G18 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-173-1114?

NSN 5925-01-173-1114 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-173-1114?

Key specifications for 5925-01-173-1114: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 500.0 AC AND 250.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 THREADED HOLE(S); Actuator Position Designation: AT POLE TWO. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-173-1114 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com