The Circuit Breaker, cataloged under National Stock Number 5925-01-161-2945, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Reliance Comm/tec Corp Lorain Products Div. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-161-2945 |
| Primary Part Number | 2567-249 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Reliance Comm/tec Corp Lorain Products Div |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP FIRST LOCATION |
| Internal Trip Release Configuration | RELAY TRIP SECOND LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC FIRST LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 24.0 DC SECOND LOCATION |
| Mounting Facility Type and Quantity | 4 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Switch Terminal Type | TURRET |
| Frequency in Hertz | 50.0 OR 60.0 FIRST LOCATION |
| Unpackaged Unit Weight | 11.000 OUNCES NOMINAL OZ |
| Center to Center Distance Between Terminals Parallel to Width | 0.995 INCHES MINIMUM AND 1.057 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Switch Voltage Rating and Type in Volts | 250.0 AC AND 50.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 FIRST LOCATION |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 120.0 SECOND LOCATION |
| External Actuator Linkage Arrangement | ONE AND TWO LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.719 INCHES MINIMUM AND 2.781 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Switch Location and Position Designation | EXTERNAL AT POLE ONE |
| Circuit Protection Type | OVERCURRENT FIRST LOCATION |
| Circuit Protection Type | OVERVOLTAGE SECOND LOCATION |
| Body Width | 2.041 INCHES MINIMUM AND 2.103 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 3.172 INCHES MINIMUM AND 3.265 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 15.0 AMPERES AC FIRST LOCATION |
| Features Provided | HIGH INRUSH PROTECTION |
| Trip Release Characteristic | INSTANTANEOUS SECOND LOCATION |
| Trip Release Characteristic | TIME DELAY FIRST LOCATION |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 2567-249 PRIMARY | Reliance Comm/tec Corp Lorain Products Div (USA) |
| Reference | Meaning |
|---|---|
| 2567-249-00 | C/1 Advisory reference — outside the item-of-supply concept Lorain Electronics Corp |
| CD2-A9-A16-DU | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
NSN 5925-01-161-2945 is a Circuit Breaker, manufactured by Reliance Comm/tec Corp Lorain Products Div, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-161-2945 has 1 manufacturer part number on file: 2567-249 (Reliance Comm/tec Corp Lorain Products Div).
1 possible match (shared part number, not a government interchangeability claim): 5925-01-205-2608. Verify interchangeability with system specifications before substitution.
Key specifications for 2567-249: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION; Internal Trip Release Configuration: RELAY TRIP SECOND LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC FIRST LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.