The Circuit Breaker, cataloged under National Stock Number 5925-01-159-6595, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Raytheon Company Div Corp. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 4 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-159-6595 |
| Primary Part Number | 996302-5 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Raytheon Company Div Corp |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SECOND LOCATION |
| Internal Trip Release Configuration | SERIES TRIP FIRST LOCATION |
| Internal Trip Release Configuration | SERIES TRIP THIRD LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC FIRST LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC SECOND LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC THIRD LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 20.0 DC FOURTH LOCATION |
| Mounting Facility Type and Quantity | 8 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 50.0 OR 400.0 FIRST LOCATION |
| Frequency in Hertz | 50.0 OR 400.0 SECOND LOCATION |
| Frequency in Hertz | 50.0 OR 400.0 THIRD LOCATION |
| Unpackaged Unit Weight | 12.500 OUNCES NOMINAL OZ |
| Center to Center Distance Between Terminals Parallel to Width | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 FIRST LOCATION |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 SECOND LOCATION |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 THIRD LOCATION |
| External Actuator Linkage Arrangement | ONE, TWO, THREE, AND FOUR LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT FIRST LOCATION |
| Circuit Protection Type | OVERCURRENT THIRD LOCATION |
| Circuit Protection Type | OVERCURRENT SECOND LOCATION |
| Circuit Protection Type | UNDERVOLTAGE FOURTH LOCATION |
| Body Width | 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 4 |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 996302-5 | Raytheon Company (USA) |
| AM4S-Z1001-1W | Heinemann Electric Canada Incdivision of Eaton Corp (CAN) |
| 996302-5 | Raytheon Company Dba Raytheon Co (USA) |
| 996302-5 PRIMARY | Raytheon Company Div Corp (USA) |
| Reference | Meaning |
|---|---|
| AM4-Z68-5 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
| AM4-Z68-5 | 5/9 Secondary reference Heinemann Electric Canada Incdivision of Eaton Corp |
NSN 5925-01-159-6595 is a Circuit Breaker, manufactured by Raytheon Company Div Corp, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-159-6595 has 4 manufacturer part numbers on file: 996302-5 (Raytheon Company), AM4S-Z1001-1W (Heinemann Electric Canada Incdivision of Eaton Corp), 996302-5 (Raytheon Company Dba Raytheon Co), 996302-5 (Raytheon Company Div Corp).
Key specifications for 996302-5: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SECOND LOCATION; Internal Trip Release Configuration: SERIES TRIP FIRST LOCATION; Internal Trip Release Configuration: SERIES TRIP THIRD LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.