The Circuit Breaker, cataloged under National Stock Number 5925-01-152-7944, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-152-7944 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 35.0 DC SECOND LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 125.0 DC FIRST LOCATION |
| Mounting Facility Type and Quantity | 4 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Unpackaged Unit Weight | 1.300 POUNDS NOMINAL LBS |
| Center to Center Distance Between Terminals Parallel to Width | 1.016 INCHES MINIMUM AND 1.036 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE AND TWO LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 2.072 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 3.475 INCHES MINIMUM AND 3.495 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES DC SECOND LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 80.0 AMPERES DC FIRST LOCATION |
| Features Provided | HIGH INRUSH PROTECTION |
| Trip Release Characteristic | INSTANTANEOUS SECOND LOCATION |
| Trip Release Characteristic | TIME DELAY FIRST LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 5000.0 DC ALL LOCATIONS |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 4.740 INCHES MINIMUM AND 4.760 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.150 MINIMUM AT 200 PCT AND 0.600 MAXIMUM AT 200 PCT FIRST LOCATION |
| Manual Actuator Type and Quantity | 2 TOGGLE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| 209-2-4298-2 | 5/2 Secondary reference U.S. Government activity |
| CD2-Z203-3 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
| SM-A-838521-2 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-152-7944 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-152-7944: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 35.0 DC SECOND LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 125.0 DC FIRST LOCATION. 30 specifications are documented in the U.S. Government catalog.