The Circuit Breaker, cataloged under National Stock Number 5925-01-152-6988, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Thales Nederland. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-152-6988 |
| Primary Part Number | 352250042486 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Thales Nederland |
| Status | ACTIVE |
| Bushing Length | 0.380 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC AND 50.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL |
| Actuator Position Designation | BETWEEN POLE ONE AND TWO |
| Switch Terminal Type | TAB, SOLDER LUG |
| Frequency in Hertz | 400.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.625 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| Switch Voltage Rating and Type in Volts | 120.0 AC AND 50.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Switch Location and Position Designation | INTERNAL AT POLE TWO |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.281 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 2 |
| Mounting Surface to Terminal End Distance | 1.828 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES AC AND 3.0 AMPERES DC ALL LOCATIONS |
| Features Provided | HIGH INRUSH PROTECTION |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 300.0 AC AND 500.0 DC ALL LOCATIONS |
| Nominal Thread Size | 0.375 INCHES IN |
| Specification/standard Data | 81349-MIL-C-39019/4 GOVERNMENT SPECIFICATION |
| Body Length | 1.562 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Switch Current Rating and Type in Amps | 0.5 AC AND 0.5 DC |
| Inclosure Protection Type for Which Designed | FUNGUS RESISTANT AND HERMETICALLY SEALED |
| Test Data Document | 81349-MIL-C-39019 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 352250042486 | Thales Nederland (NLD) |
| Reference | Meaning |
|---|---|
| M39019/4-317 | C/1 Advisory reference — outside the item-of-supply concept U.S. Government activity |
| M39019/04-317 | 2/2 Government specification standardization U.S. Government activity |
| MIL-C-39019/4 | 5/9 Secondary reference U.S. Government activity |
| MIL-PRF-39019/4 | 4/1 Identification reference U.S. Government activity |
NSN 5925-01-152-6988 is a Circuit Breaker, manufactured by Thales Nederland, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-152-6988 has 1 manufacturer part number on file: 352250042486 (Thales Nederland).
Key specifications for 352250042486: Bushing Length: 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.