The Circuit Breaker, cataloged under National Stock Number 5925-01-150-4464, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Cole Hersee Company. Government technical data includes 20 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-150-4464 |
| Primary Part Number | 3088-50 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Cole Hersee Company |
| Status | ACTIVE |
| Reset Method | AUTOMATIC |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 24.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 2 TERMINAL |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | RECTANGULAR DIMENSIONAL ENVELOPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Unthreaded Mounting Hole Diameter | 0.210 INCHES MINIMUM AND 0.230 INCHES MAXIMUM IN |
| Pole Quantity | 2 |
| Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES DC ALL LOCATIONS |
| Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 DC ALL LOCATIONS |
| Inclosure Protection Type for Which Designed | HERMETICALLY SEALED |
| Trip Release Ambient Temp Rating | 25.0 CELSIUS NOMINAL ALL LOCATIONS DEGC |
| Terminal Type and Quantity | 4 THREADED STUD |
| Special Handling Feature | MAGNETIC |
| Trip Release Method | THERMAL ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 3088-50 PRIMARY | Cole Hersee Company (USA) |
| Reference | Meaning |
|---|---|
| 201035 | C/1 Advisory reference — outside the item-of-supply concept Wiggins Lift Co Inc |
| 3088-50 | C/1 Advisory reference — outside the item-of-supply concept Made-Rite Tool Co Inc |
NSN 5925-01-150-4464 is a Circuit Breaker, manufactured by Cole Hersee Company, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-150-4464 has 1 manufacturer part number on file: 3088-50 (Cole Hersee Company).
Key specifications for 3088-50: Reset Method: AUTOMATIC; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 24.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 2 TERMINAL. 20 specifications are documented in the U.S. Government catalog.