PartsTable TECHNICAL DATA SHEET
NSN 5925-01-149-9359Government record, cited

Circuit Breaker5925-01-149-9359

NSN 5925-01-149-9359 · NIIN 011499359
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-149-9359 · 5925011499359 · NIIN 011499359 · 01-149-9359 · FSC 5925 Circuit Breakers · KD1-1.5A · KD1-1R5
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 32.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 1 CLIP
  • Actuator Position Designation: AT POLE ONE
  • Frequency in Hertz: 50.0 OR 60.0 SINGLE LOCATION
  • Body Style: SINGLE POLE TYPE
Identification
  • NSN: 5925-01-149-9359
  • NIIN: 011499359
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-149-9359, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 25 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-149-9359
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts240.0 AC AND 32.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity1 CLIP
Actuator Position DesignationAT POLE ONE
Frequency in Hertz50.0 OR 60.0 SINGLE LOCATION
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent135.0 SINGLE LOCATION
Overall Diameter0.635 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Maximum Continuous Load Current Rating Per Pole1.5 AMPERES AC AND 1.5 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 AC AND 200.0 DC SINGLE LOCATION
Body Length2.150 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current4.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 PUSH BUTTON
Inclosure Protection Type for Which DesignedGENERAL PURPOSE
MaterialPLASTIC CASE
Actuator FunctionRESET
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Terminal Type and Quantity2 QUICK DISCONNECT, MALE
Main Contact Tripping Mechanism TypeTRIP FREE
Trip Release MethodTHERMAL SINGLE LOCATION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
KD1-1.5A 3/9 Design control — primary reference
Eaton Corp Heinemann Products Commercial Controls Div
KD1-1R5 3/2 Design control — primary reference
U.S. Government activity
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-149-9359?

NSN 5925-01-149-9359 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-149-9359?

Key specifications for 5925-01-149-9359: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 32.0 DC SINGLE LOCATION; Mounting Facility Type and Quantity: 1 CLIP. 25 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-149-9359 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com