PartsTable TECHNICAL DATA SHEET
NSN 5925-01-137-0159Government record, cited

Circuit Breaker5925-01-137-0159

NSN 5925-01-137-0159 · NIIN 011370159 · Part number EH2-B050-F2
L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc. · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE 30086
Government record, cited
NSN 5925-01-137-0159 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-137-0159. Manufacturer of record part number: EH2-B050-F2.
Also searched as  5925-01-137-0159 · 5925011370159 · NIIN 011370159 · 01-137-0159 · FSC 5925 Circuit Breakers · CAGE 30086 · EH2-B050-F2 · G376972-7
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.203 INCHES MINIMUM AND 0.235 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Switch Terminal Type: WIRE LEAD
  • Frequency in Hertz: 60.0 ALL LOCATIONS
Identification
  • NSN: 5925-01-137-0159
  • NIIN: 011370159
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: EH2-B050-F2
  • Manufacturer: L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc.
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-137-0159, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc.. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-137-0159
Primary Part NumberEH2-B050-F2
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerL3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc.
StatusACTIVE
Bushing Length0.203 INCHES MINIMUM AND 0.235 INCHES MAXIMUM IN
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity2 UNTHREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Switch Terminal TypeWIRE LEAD
Frequency in Hertz60.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width1.484 INCHES MINIMUM AND 1.516 INCHES MAXIMUM IN
Fragility FactorMODERATELY RUGGED
Body StyleMULTIPOLE-MULTIPLE ACTUATOR TYPE
Switch Voltage Rating and Type in Volts240.0 AC AND 250.0 DC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent125.0 ALL LOCATIONS
Distance Between Centerlines of Mounting Facilities Parallel to Body Length4.578 INCHES MINIMUM AND 4.610 INCHES MAXIMUM IN
Switch Location and Position DesignationINTERNAL BETWEEN POLE ONE AND TWO
Precious MaterialSILVER
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width2.984 INCHES MINIMUM AND 3.010 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.164 INCHES NOMINAL IN
Pole Quantity2
Mounting Surface to Terminal End Distance3.984 INCHES MINIMUM AND 4.016 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole50.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicINSTANTANEOUS ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps15000.0 AC ALL LOCATIONS
Body Length5.984 INCHES MINIMUM AND 6.016 INCHES MAXIMUM IN
Manual Actuator Type and Quantity1 TOGGLE
Switch Current Rating and Type in Amps15.0 AC AND 0.25 DC
Inclosure Protection Type for Which DesignedFUNGUS PROOF
Precious Material and LocationTERMINAL AND CONTACT SURFACES SILVER
Switch Contact ArrangementSINGLE POLE, DOUBLE THROW
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
EH2-B050-F2 PRIMARY L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc. (USA)
Reference documents
ReferenceMeaning
G376972-7 5/9 Secondary reference
Lucent Technologies Inc Advanced Technology Systems
EH2-B050-F2 5/1 Secondary reference
Siemens Energy and Automation Inc Ite Circuit Protection Div
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-137-0159?

NSN 5925-01-137-0159 is a Circuit Breaker, manufactured by L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc., classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-01-137-0159?

NSN 5925-01-137-0159 has 1 manufacturer part number on file: EH2-B050-F2 (L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc.).

What are the specifications of EH2-B050-F2?

Key specifications for EH2-B050-F2: Bushing Length: 0.203 INCHES MINIMUM AND 0.235 INCHES MAXIMUM IN; Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 2 UNTHREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-137-0159 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com