The Circuit Breaker, cataloged under National Stock Number 5925-01-123-2829, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-123-2829 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 8 THREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Switch Terminal Type | QUICK DISCONNECT, MALE |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Unpackaged Unit Weight | 14.800 OUNCES NOMINAL OZ |
| Center to Center Distance Between Terminals Parallel to Width | 0.715 INCHES MINIMUM AND 0.745 INCHES MAXIMUM IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Switch Voltage Rating and Type in Volts | 250.0 AC AND 50.0 DC |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE, TWO, THREE, AND FOUR LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM IN |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Switch Location and Position Designation | INTERNAL AT POLE FOUR |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 2.990 INCHES MINIMUM AND 3.010 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 4 |
| Mounting Surface to Terminal End Distance | 1.835 INCHES MAXIMUM IN |
| Maximum Continuous Load Current Rating Per Pole | 100.0 MILLIAMPERES AC FOURTH LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 72.0 AMPERES AC FIRST LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 72.0 AMPERES AC SECOND LOCATION |
| Maximum Continuous Load Current Rating Per Pole | 72.0 AMPERES AC THIRD LOCATION |
| Features Provided | HIGH INRUSH PROTECTION |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 5000.0 AC ALL LOCATIONS |
| Nominal Thread Size | 0.138 INCHES IN |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Reference | Meaning |
|---|---|
| AM4-A8A8A8A9-A-72/72/72/0.1-20 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
| APL-1111-1REC2-6588-12 | 5/2 Secondary reference U.S. Government activity |
| 8560939-12 | 3/9 Design control — primary reference Lockheed Martin Corporation Dba Lockheed Martin Div Lockheed Martin |
NSN 5925-01-123-2829 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.
Key specifications for 5925-01-123-2829: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 8 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.