PartsTable TECHNICAL DATA SHEET
NSN 5925-01-116-5461Government record, cited

Circuit Breaker5925-01-116-5461

NSN 5925-01-116-5461 · NIIN 011165461
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-116-5461 · 5925011165461 · NIIN 011165461 · 01-116-5461 · FSC 5925 Circuit Breakers · T11-0-10.0A-02-10-A · T11-1-10.0A-02-31A-V · 31H4-100
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.458 INCHES MINIMUM AND 0.478 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION
  • Operating Voltage Type and Rating Per Pole in Volts: 32.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING
  • Actuator Position Designation: BETWEEN POLE ONE AND TWO
  • Fragility Factor: MODERATELY RUGGED
Identification
  • NSN: 5925-01-116-5461
  • NIIN: 011165461
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-116-5461, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 3 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-116-5461
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.458 INCHES MINIMUM AND 0.478 INCHES MAXIMUM IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP SINGLE LOCATION
Operating Voltage Type and Rating Per Pole in Volts32.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity1 THREADED BUSHING
Actuator Position DesignationBETWEEN POLE ONE AND TWO
Fragility FactorMODERATELY RUGGED
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent135.0 SINGLE LOCATION
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.670 INCHES MINIMUM AND 0.690 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance2.022 INCHES MINIMUM AND 2.102 INCHES MAXIMUM IN
Maximum Continuous Load Current Rating Per Pole10.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps1000.0 DC SINGLE LOCATION
Nominal Thread Size0.500 INCHES IN
Body Length1.294 INCHES MINIMUM AND 1.310 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current0.100 MINIMUM AT 200 PCT AND 2.000 MAXIMUM AT 200 PCT SINGLE LOCATION
Manual Actuator Type and Quantity1 TOGGLE
Inclosure Protection Type for Which DesignedSHOCK RESISTANT AND VIBRATION RESISTANT
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Terminal Type and Quantity2 QUICK DISCONNECT, FEMALE
Special Handling FeatureMAGNETIC
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUN
Trip Release MethodMAGNETIC SINGLE LOCATION
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5925-01-138-4059T11-1-10.0A-02-31A-V POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)Sensata Technologies Maryland, Inc
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
T11-0-10.0A-02-10-A 5/9 Secondary reference
U.S. Government activity
T11-1-10.0A-02-31A-V 3/2 Design control — primary reference
U.S. Government activity
31H4-100 1/2 Source control — Government-approved source
U.S. Government activity
Related Parts
5925-01-138-4059POSSIBLE MATCH
CIRCUIT BREAKER
T11-1-10.0A-02-31A-V

Frequently Asked Questions

What is NSN 5925-01-116-5461?

NSN 5925-01-116-5461 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-116-5461?

1 possible match (shared part number, not a government interchangeability claim): 5925-01-138-4059. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-116-5461?

Key specifications for 5925-01-116-5461: Bushing Length: 0.458 INCHES MINIMUM AND 0.478 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 32.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-116-5461 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com