The Circuit Breaker, cataloged under National Stock Number 5925-01-113-7793, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Heinemann Electric Canada Incdivision of Eaton Corp. Government technical data includes 29 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 4 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-113-7793 |
| Primary Part Number | CD6-A2A3A3A3A3A3-DU-W-25-120/240 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Heinemann Electric Canada Incdivision of Eaton Corp |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 12 THREADED STUD(S) AND 12 UNTHREADED HOLE(S) |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 50.0 OR 60.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 1.032 INCHES NOMINAL IN |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 125.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE, TWO, THREE, FOUR, FIVE, AND SIX LINKED |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Length | 2.750 INCHES MINIMUM IN |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 6.192 INCHES NOMINAL IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Unthreaded Mounting Hole Diameter | 0.156 INCHES NOMINAL IN |
| Pole Quantity | 6 |
| Mounting Surface to Terminal End Distance | 2.609 INCHES NOMINAL IN |
| Maximum Continuous Load Current Rating Per Pole | 25.0 AMPERES AC ALL LOCATIONS |
| Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 5000.0 AC ALL LOCATIONS |
| Nominal Thread Size | 0.138 INCHES IN |
| Body Length | 5.844 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 40.000 MINIMUM AT 200 PCT AND 100.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 6 TOGGLE |
| Distance Between Centerlines of Mounting Facilities Parallel to Body Width | 1.032 INCHES NOMINAL IN |
| Inclosure Protection Type for Which Designed | CORROSION RESISTANT AND HUMIDITY RESISTANT AND FUNGUS RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| Thread Quantity Per Inch | 32 |
| Material | PLASTIC CASE |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| CD6-A2A3A3A3A3A3-DU-W-25-120/240 | Heinemann Electric Canada Incdivision of Eaton Corp (CAN) |
| Reference | Meaning |
|---|---|
| CD6-Z10-1 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
| CD6A2A32524050/601 | C/1 Advisory reference — outside the item-of-supply concept Eaton Corp Heinemann Products Commercial Controls Div |
| CD6-A2A3A3A3A3A3-DU-25-120/240-1 | 5/9 Secondary reference Eaton Corp Heinemann Products Commercial Controls Div |
| SM-A-949338-6 | 3/2 Design control — primary reference U.S. Government activity |
NSN 5925-01-113-7793 is a Circuit Breaker, manufactured by Heinemann Electric Canada Incdivision of Eaton Corp, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-113-7793 has 1 manufacturer part number on file: CD6-A2A3A3A3A3A3-DU-W-25-120/240 (Heinemann Electric Canada Incdivision of Eaton Corp).
Key specifications for CD6-A2A3A3A3A3A3-DU-W-25-120/240: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 12 THREADED STUD(S) AND 12 UNTHREADED HOLE(S). 29 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.