The Circuit Breaker, cataloged under National Stock Number 5925-01-111-4506, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Raytheon Company Div Rmd Strategic. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 1 additional reference document (drawings, advisory and superseded references) is recorded in the U.S. Government catalog. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-111-4506 |
| Primary Part Number | 711547-3 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Raytheon Company Div Rmd Strategic |
| Status | ACTIVE |
| Bushing Length | 0.380 INCHES MAXIMUM IN |
| Reset Method | MANUAL |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC AND 50.0 DC SINGLE LOCATION |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL |
| Actuator Position Designation | AT POLE ONE |
| Frequency in Hertz | 400.0 SINGLE LOCATION |
| Unpackaged Unit Weight | 1.800 OUNCES NOMINAL OZ |
| Fragility Factor | MODERATELY RUGGED |
| Body Style | SINGLE POLE TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 115.0 SINGLE LOCATION |
| Arc Quenching Method | MAGNETIC BLOWOUT |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Body Width | 0.625 INCHES MAXIMUM IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 1 |
| Mounting Surface to Terminal End Distance | 1.605 INCHES MAXIMUM IN |
| Thread Pitch Diameters | +0.3503 TO 0.3537 INCHES IN |
| Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES AC AND 20.0 AMPERES DC SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC AND 1000.0 DC SINGLE LOCATION |
| Nominal Thread Size | 0.375 INCHES IN |
| Body Length | 1.562 INCHES MAXIMUM IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.070 MINIMUM AT 200 PCT AND 0.700 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Inclosure Protection Type for Which Designed | HERMETICALLY SEALED AND SHOCKPROOF AND VIBRATIONPROOF |
| Thread Quantity Per Inch | 32 |
| Actuator Function | TRIP-RESET |
| Terminal Type and Quantity | 2 WIRE HOOK |
| Special Handling Feature | MAGNETIC |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
| Part Number | Manufacturer |
|---|---|
| 711547-3 PRIMARY | Raytheon Company Div Rmd Strategic (USA) |
| Reference | Meaning |
|---|---|
| AP-1-5680-3 | 5/2 Secondary reference U.S. Government activity |
NSN 5925-01-111-4506 is a Circuit Breaker, manufactured by Raytheon Company Div Rmd Strategic, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-111-4506 has 1 manufacturer part number on file: 711547-3 (Raytheon Company Div Rmd Strategic).
Key specifications for 711547-3: Bushing Length: 0.380 INCHES MAXIMUM IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP SINGLE LOCATION; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC SINGLE LOCATION. 30 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.