Features
  • Circuit Breaker — FSC 5925
  • Reset Method: AUTOMATIC
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S)
  • Switch Terminal Type: PIN
  • Frequency in Hertz: 400.0 ALL LOCATIONS
  • Unpackaged Unit Weight: 2.250 POUNDS NOMINAL LBS
Identification
  • NSN: 5925-01-110-1785
  • NIIN: 011101785
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-110-1785, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 27 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-110-1785
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodAUTOMATIC
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts200.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S)
Switch Terminal TypePIN
Frequency in Hertz400.0 ALL LOCATIONS
Unpackaged Unit Weight2.250 POUNDS NOMINAL LBS
Body StyleRECTANGULAR DIMENSIONAL ENVELOPE
Switch Voltage Rating and Type in Volts115.0 AC AND 28.0 DC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent138.0 ALL LOCATIONS
Switch Location and Position DesignationINTERNAL AT POLE THREE
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.172 INCHES NOMINAL IN
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole40.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps3600.0 AC ALL LOCATIONS
Trip Delay Time in Seconds Per Rated Continuous Current16.000 MINIMUM AT 200 PCT AND 80.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Switch Current Rating and Type in Amps3.0 AC AND 3.0 DC
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT AND MOISTURE RESISTANT
Switch Contact ArrangementSINGLE POLE, DOUBLE THROW
MaterialPLASTIC CASE
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Terminal Type and Quantity6 THREADED STUD
Trip Release MethodTHERMAL ALL LOCATIONS
Auxiliary Switch Function and Quantity1 ALARM
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
SM601BA40A1 3/2 Design control — primary reference
U.S. Government activity
5925PL1940184 6/9 Informative reference only
Jednolity Indeks Materialowy - Uniform Material Index
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-110-1785?

NSN 5925-01-110-1785 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What are the specifications of 5925-01-110-1785?

Key specifications for 5925-01-110-1785: Reset Method: AUTOMATIC; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S). 27 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-110-1785 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com