The Circuit Breaker, cataloged under National Stock Number 5925-01-100-0636, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Alliant Techsystems Operations Llc Div Defense Electronic Systems. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 2 commercial cross-references from 2 manufacturers, enabling identification through both NSN and commercial part number lookups. 2 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-100-0636 |
| Primary Part Number | 10527-6 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — No Item Name Available |
| Manufacturer | Alliant Techsystems Operations Llc Div Defense Electronic Systems |
| Status | ACTIVE |
| Trip Delay Time in Seconds Per Rated Continuous Current | 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT SINGLE LOCATION |
| Trip Release Method | MAGNETIC SINGLE LOCATION |
| Actuator Function | TRIP-RESET |
| Operating Voltage Type and Rating Per Pole in Volts | 240.0 AC AND 50.0 DC SINGLE LOCATION |
| Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
| Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 115.0 SINGLE LOCATION |
| Actuator Position Designation | AT POLE ONE |
| Reset Method | MANUAL |
| Thread Series Designator | UNEF |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Maximum Continuous Load Current Rating Per Pole | 500.0 MILLIAMPERES AC AND 500.0 MILLIAMPERES DC SINGLE LOCATION |
| Frequency in Hertz | 400.0 SINGLE LOCATION |
| Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
| Body Width | 0.625 INCHES MAXIMUM IN |
| Inclosure Protection Type for Which Designed | CORROSION RESISTANT AND HERMETICALLY SEALED AND HUMIDITY RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT |
| Nominal Thread Size | 0.375 INCHES IN |
| Manual Actuator Type and Quantity | 1 TOGGLE |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 1000.0 AC AND 1000.0 DC SINGLE LOCATION |
| Terminal Type and Quantity | 2 WIRE HOOK |
| Special Handling Feature | MAGNETIC |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Mounting Surface to Terminal End Distance | 1.574 INCHES MINIMUM AND 1.636 INCHES MAXIMUM IN |
| Pole Quantity | 1 |
| Center to Center Distance Between Terminals Parallel to Length | 0.844 INCHES MINIMUM AND 0.906 INCHES MAXIMUM IN |
| Mounting Facility Type and Quantity | 1 THREADED BUSHING WITH PANEL SEAL |
| Fragility Factor | MODERATELY RUGGED |
| Thread Quantity Per Inch | 32 |
| Body Length | 1.500 INCHES MAXIMUM IN |
| Body Style | SINGLE POLE TYPE |
| Acquisition Status | ACTIVE |
| HAZMAT | No |
| Part Number | Manufacturer |
|---|---|
| 10527-6 PRIMARY | Alliant Techsystems Operations Llc Div Defense Electronic Systems (USA) |
| AP1-2508-6 | Sensata Technologies Maryland, Inc (USA) |
NSN 5925-01-100-0636 is a Circuit Breaker, manufactured by Alliant Techsystems Operations Llc Div Defense Electronic Systems, classified under FSC 5925 (No Item Name Available). Status: active.
NSN 5925-01-100-0636 has 2 cross-referenced part numbers: 10527-6 (Alliant Techsystems Operations Llc Div Defense Electronic Systems), AP1-2508-6 (Sensata Technologies Maryland, Inc).
There are 2 known substitutes for 5925-01-100-0636: 5935-00-259-3273, 2010-01-439-7906. Verify interchangeability with system specifications before substitution.
Key specifications for 10527-6: Trip Delay Time in Seconds Per Rated Continuous Current: 0.055 MINIMUM AT 200 PCT AND 0.950 MAXIMUM AT 200 PCT SINGLE LOCATION; Trip Release Method: MAGNETIC SINGLE LOCATION; Actuator Function: TRIP-RESET; Operating Voltage Type and Rating Per Pole in Volts: 240.0 AC AND 50.0 DC SINGLE LOCATION. 30 total characteristics are documented in the Federal Logistics Information System.