PartsTable TECHNICAL DATA SHEET
JULY 2026Technical Data Sheet

W-C-375/2Circuit Breaker

Federal Specifications Promulgated by General Services Administration Washington DC · NSN 5925-01-096-4677 · FSC 5925 · No Item Name Available
Verified by PartsTable
NSN 5925-01-096-4677 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-096-4677. Primary manufacturer part number: W-C-375/2.
Features
  • Circuit Breaker — FSC 5925
  • Trip Release Method: THERMAL-MAGNETIC ALL LOCATIONS
  • Inclosure Protection Type for Which Designed: CORROSION RESISTANT
  • Manual Actuator Type and Quantity: 1 TOGGLE
  • Actuator Position Designation: AT POLE TWO
  • Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent: 135.0 ALL LOCATIONS
  • Specification/standard Data: 81348-W-C-375/2 GOVERNMENT SPECIFICATION
  • Test Data Document: 81348-W-C-375 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Applications
  • Applications requiring Plastic Case construction
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-096-4677, is classified within Federal Supply Class 5925 (No Item Name Available) of the Electrical and Electronic Equipment Components group. The primary manufacturer of record is Federal Specifications Promulgated by General Services Administration Washington DC. Government technical data includes 30 verified specifications, sourced from the Federal Logistics Information System (FLIS). This item has 2 commercial cross-references from 1 manufacturer, enabling identification through both NSN and commercial part number lookups. 8 verified substitutes exist in the FLIS interchangeability database. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-096-4677
Primary Part NumberW-C-375/2
Item NameCircuit Breaker
FSC / FSG5925 / 59 — No Item Name Available
ManufacturerFederal Specifications Promulgated by General Services Administration Washington DC
StatusACTIVE
Trip Release MethodTHERMAL-MAGNETIC ALL LOCATIONS
Inclosure Protection Type for Which DesignedCORROSION RESISTANT
Manual Actuator Type and Quantity1 TOGGLE
Actuator Position DesignationAT POLE TWO
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent135.0 ALL LOCATIONS
Specification/standard Data81348-W-C-375/2 GOVERNMENT SPECIFICATION
Test Data Document81348-W-C-375 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Reset MethodMANUAL
Actuator FunctionTRIP-RESET
Frequency in Hertz60.0 ALL LOCATIONS
Maximum Continuous Load Current Rating Per Pole20.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
MaterialPLASTIC CASE
Trip Delay Time in Seconds Per Rated Continuous Current2.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Terminal Type and Quantity2 CLIP AND 2 COMPRESSION
Operating Voltage Type and Rating Per Pole in Volts240.0 AC ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps10000.0 AC ALL LOCATIONS
Main Contact Tripping Mechanism TypeTRIP FREE
Center to Center Distance Between Terminals Parallel to Width0.740 INCHES NOMINAL IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Boss Height0.250 INCHES NOMINAL IN
Fragility FactorMODERATELY RUGGED
Special Handling FeatureMAGNETIC
Pole Quantity2
Mounting Facility Type and Quantity4 TERMINAL
Body Length3.000 INCHES NOMINAL IN
Body Height2.580 INCHES NOMINAL IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Lifecycle & Compliance
Acquisition StatusACTIVE
HAZMATNo
Verified Substitutes 8
5925-00-513-2532 INTERCHANGEABLE
Circuit Breaker
5925-00-958-6828 INTERCHANGEABLE
Circuit Breaker
5925-01-092-9573 INTERCHANGEABLE
Circuit Breaker
5925-01-099-0371 INTERCHANGEABLE
Circuit Breaker
5925-01-099-0372 INTERCHANGEABLE
Circuit Breaker
5925-01-099-8648 INTERCHANGEABLE
Circuit Breaker
5925-01-147-8574 INTERCHANGEABLE
Circuit Breaker
5925-01-218-5420 INTERCHANGEABLE
Circuit Breaker
Cross-Reference Index
Part NumberManufacturer
W-C-375/2 Federal Specifications Promulgated by General Services Administration Washington DC (USA)
WC375/02-002 Federal Specifications Promulgated by General Services Administration Washington DC (USA)
Related Parts
5925-00-513-2532INTERCHANGEABLE
CIRCUIT BREAKER
5925-00-958-6828INTERCHANGEABLE
CIRCUIT BREAKER
5925-01-092-9573INTERCHANGEABLE
CIRCUIT BREAKER
5925-01-099-0371INTERCHANGEABLE
CIRCUIT BREAKER
5925-01-099-0372INTERCHANGEABLE
CIRCUIT BREAKER
5925-01-099-8648INTERCHANGEABLE
CIRCUIT BREAKER
5925-01-147-8574INTERCHANGEABLE
CIRCUIT BREAKER
5925-01-218-5420INTERCHANGEABLE
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-096-4677?

NSN 5925-01-096-4677 is a Circuit Breaker, manufactured by Federal Specifications Promulgated by General Services Administration Washington DC, classified under FSC 5925 (No Item Name Available). Status: active.

What are the part numbers for NSN 5925-01-096-4677?

NSN 5925-01-096-4677 has 2 cross-referenced part numbers: W-C-375/2 (Federal Specifications Promulgated by General Services Administration Washington DC), WC375/02-002 (Federal Specifications Promulgated by General Services Administration Washington DC).

What NSN replaces 5925-01-096-4677?

There are 8 known substitutes for 5925-01-096-4677: 5925-00-513-2532, 5925-00-958-6828, 5925-01-092-9573 and 5 more. Verify interchangeability with system specifications before substitution.

What are the specifications of W-C-375/2?

Key specifications for W-C-375/2: Trip Release Method: THERMAL-MAGNETIC ALL LOCATIONS; Inclosure Protection Type for Which Designed: CORROSION RESISTANT; Manual Actuator Type and Quantity: 1 TOGGLE; Actuator Position Designation: AT POLE TWO. 30 total characteristics are documented in the Federal Logistics Information System.

Validated with multiple authoritative sources, including Government, OEM, and Certified sources.
PartsTable Design LLC · partstable.com