Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.280 INCHES MAXIMUM IN
  • Reset Method: MANUAL
  • Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 30.0 DC SINGLE LOCATION
  • Mounting Facility Type and Quantity: 2 THREADED HOLE(S)
  • Actuator Position Designation: AT POLE ONE
  • Frequency in Hertz: 400.0 SINGLE LOCATION
  • Unpackaged Unit Weight: 0.200 POUNDS NOMINAL LBS
Identification
  • NSN: 5925-01-095-6397
  • NIIN: 010956397
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-095-6397, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 30 specifications, cited from the U.S. Government catalog. 7 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 1 item shares a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-095-6397
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Bushing Length0.280 INCHES MAXIMUM IN
Reset MethodMANUAL
Operating Voltage Type and Rating Per Pole in Volts120.0 AC AND 30.0 DC SINGLE LOCATION
Mounting Facility Type and Quantity2 THREADED HOLE(S)
Actuator Position DesignationAT POLE ONE
Frequency in Hertz400.0 SINGLE LOCATION
Unpackaged Unit Weight0.200 POUNDS NOMINAL LBS
Body StyleSINGLE POLE TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent138.0 SINGLE LOCATION
Distance Between Centerlines of Mounting Facilities Parallel to Body Length1.810 INCHES NOMINAL IN
Circuit Protection TypeOVERCURRENT SINGLE LOCATION
Body Width0.760 INCHES MAXIMUM IN
Storage TypeGENERAL PURPOSE WAREHOUSE
Pole Quantity1
Mounting Surface to Terminal End Distance2.370 INCHES NOMINAL IN
Maximum Continuous Load Current Rating Per Pole20.0 AMPERES AC AND 20.0 AMPERES DC SINGLE LOCATION
Trip Release CharacteristicTIME DELAY SINGLE LOCATION
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps6000.0 AC AND 6000.0 DC SINGLE LOCATION
Nominal Thread Size0.138 INCHES IN
Body Length2.189 INCHES MAXIMUM IN
Trip Delay Time in Seconds Per Rated Continuous Current20.000 MINIMUM AT 200 PCT AND 50.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 PUSH-PULL
Inclosure Protection Type for Which DesignedFUNGUS RESISTANT
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL SINGLE LOCATION DEGC
Terminal Type and Quantity2 SCREW
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNIFIED NATIONAL COARSE (UNC)
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 1
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5925-01-172-85106752-12-20 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)Sensata Technologies, Inc. Div Sensata Attleboro
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
10-30108-20 5/2 Secondary reference
U.S. Government activity
6752-12-20 5/2 Secondary reference
U.S. Government activity
10-30108-20 3/2 Design control — primary reference
U.S. Government activity
1901-00-20 5/9 Secondary reference
Safran Electrical & Power Usa, Llc Dba Labinal Power Sysyems Use CAGE Code 81640 for Cataloging
1901-003-20 5/2 Secondary reference
U.S. Government activity
6752-11-20 5/9 Secondary reference
U.S. Government activity
BM-10-20 5/9 Secondary reference
U.S. Government activity
Related Parts
5925-01-172-8510POSSIBLE MATCH
CIRCUIT BREAKER
6752-12-20

Frequently Asked Questions

What is NSN 5925-01-095-6397?

NSN 5925-01-095-6397 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-095-6397?

1 possible match (shared part number, not a government interchangeability claim): 5925-01-172-8510. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-095-6397?

Key specifications for 5925-01-095-6397: Bushing Length: 0.280 INCHES MAXIMUM IN; Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC AND 30.0 DC SINGLE LOCATION; Mounting Facility Type and Quantity: 2 THREADED HOLE(S). 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-095-6397 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com