The Circuit Breaker, cataloged under National Stock Number 5925-01-095-1995, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Naval Sea Systems Command. Government technical data includes 29 specifications, cited from the U.S. Government catalog. The record lists 3 manufacturer part numbers for this item, enabling identification through both NSN and commercial part number lookups. Current acquisition status: Active.
| Parameter | Value |
|---|---|
| NSN | 5925-01-095-1995 |
| Primary Part Number | 5192968-4 |
| Item Name | Circuit Breaker |
| FSC / FSG | 5925 / 59 — Circuit Breakers |
| Manufacturer | Naval Sea Systems Command |
| Status | ACTIVE |
| Reset Method | MANUAL |
| Operating Voltage Type and Rating Per Pole in Volts | 125.0 AC AND 125.0 DC ALL LOCATIONS |
| Mounting Facility Type and Quantity | 2 CLIP |
| Actuator Position Designation | AT EACH POLE |
| Frequency in Hertz | 60.0 ALL LOCATIONS |
| Center to Center Distance Between Terminals Parallel to Width | 0.969 INCHES NOMINAL IN |
| Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent | 138.0 ALL LOCATIONS |
| External Actuator Linkage Arrangement | ONE AND TWO LINKED |
| Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| Body Width | 1.938 INCHES NOMINAL IN |
| Body Height | 2.312 INCHES NOMINAL IN |
| Storage Type | GENERAL PURPOSE WAREHOUSE |
| Pole Quantity | 2 |
| Maximum Continuous Load Current Rating Per Pole | 10.0 AMPERES AC AND 10.0 AMPERES DC ALL LOCATIONS |
| Trip Release Characteristic | INSTANTANEOUS AND TIME DELAY ALL LOCATIONS |
| Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps | 5000.0 AC AND 2500.0 DC ALL LOCATIONS |
| Body Length | 3.500 INCHES NOMINAL IN |
| Trip Delay Time in Seconds Per Rated Continuous Current | 10.000 MINIMUM AT 200 PCT AND 180.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| Manual Actuator Type and Quantity | 2 TOGGLE |
| Inclosure Protection Type for Which Designed | CORROSION RESISTANT |
| Material | PLASTIC CASE |
| Actuator Function | TRIP-RESET |
| Trip Release Ambient Temp Rating | 50.0 CELSIUS NOMINAL ALL LOCATIONS DEGC |
| Terminal Type and Quantity | 4 SCREW |
| Special Handling Feature | MAGNETIC |
| Main Contact Tripping Mechanism Type | TRIP FREE |
| Boss Height | 0.188 INCHES NOMINAL IN |
| Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
| Acquisition Status | ACTIVE |
| DEMIL Code | DEMIL A — No Demilitarization Required |
| Hazard | Possible hazard — SDS may be required (DLA HMIC P) |
| Criticality Code | X |
NSN 5925-01-095-1995 is a Circuit Breaker, manufactured by Naval Sea Systems Command, classified under FSC 5925, Circuit Breakers. Status: active.
NSN 5925-01-095-1995 has 3 manufacturer part numbers on file: 5192968-4 (General Electric Co Electrical Distribution and Control), 5192968-4 (L3harris Maritime Power & Energy Solutions, Inc. Dba Spd Electrical Systems, Inc.), 5192968-4 (Naval Sea Systems Command).
Key specifications for 5192968-4: Reset Method: MANUAL; Operating Voltage Type and Rating Per Pole in Volts: 125.0 AC AND 125.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 2 CLIP; Actuator Position Designation: AT EACH POLE. 29 specifications are documented in the U.S. Government catalog.
Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.
U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.