PartsTable TECHNICAL DATA SHEET
NSN 5925-01-086-7424Government record, cited

Circuit Breaker5925-01-086-7424

NSN 5925-01-086-7424 · NIIN 010867424 · Part number B77611
Mbda Uk Ltd · FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components · CAGE K0967
Government record, cited
NSN 5925-01-086-7424 — this item is cataloged by the U.S. Government under National Stock Number 5925-01-086-7424. Manufacturer of record part number: B77611.
Also searched as  5925-01-086-7424 · 5925010867424 · NIIN 010867424 · 01-086-7424 · FSC 5925 Circuit Breakers · CAGE K0967 · B77611 · 9TC2-15 · 7910296-01
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Bushing Length: 0.250 INCHES NOMINAL IN
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 1 THREADED BUSHING
  • Actuator Position Designation: AT POLE TWO
  • Frequency in Hertz: 400.0 ALL LOCATIONS
Identification
  • NSN: 5925-01-086-7424
  • NIIN: 010867424
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
  • Primary part number: B77611
  • Manufacturer: Mbda Uk Ltd
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-086-7424, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. The manufacturer of record is Mbda Uk Ltd. Government technical data includes 30 specifications, cited from the U.S. Government catalog. The record lists 1 manufacturer part number for this item, enabling identification through both NSN and commercial part number lookups. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-086-7424
Primary Part NumberB77611
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
ManufacturerMbda Uk Ltd
StatusACTIVE
Bushing Length0.250 INCHES NOMINAL IN
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts120.0 AC ALL LOCATIONS
Mounting Facility Type and Quantity1 THREADED BUSHING
Actuator Position DesignationAT POLE TWO
Frequency in Hertz400.0 ALL LOCATIONS
Center to Center Distance Between Terminals Parallel to Width0.770 INCHES MINIMUM AND 0.834 INCHES MAXIMUM IN
Body StyleMULTIPOLE-SINGLE ACTUATOR TYPE
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent145.0 ALL LOCATIONS
External Actuator Linkage ArrangementONE, TWO, AND THREE LINKED
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Body Width1.100 INCHES MAXIMUM IN
Body Height1.350 INCHES NOMINAL IN
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole15.0 AMPERES AC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps2000.0 AC ALL LOCATIONS
Nominal Thread Size0.438 INCHES IN
Body Length2.380 INCHES NOMINAL IN
Trip Delay Time in Seconds Per Rated Continuous Current4.000 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT AND 0.400 MINIMUM AT 500 PCT AND 2.000 MAXIMUM AT 500 PCT AND 0.100 MINIMUM AT 1000 PCT AND 0.530 MAXIMUM AT 1000 PCT ALL LOCATIONS
Manual Actuator Type and Quantity1 PUSH-PULL
Thread Quantity Per Inch32
MaterialPLASTIC CASE
Actuator FunctionTRIP-RESET
Trip Release Ambient Temp Rating25.0 CELSIUS MAXIMUM ALL LOCATIONS DEGC
Terminal Type and Quantity6 SCREW
Main Contact Tripping Mechanism TypeTRIP FREE
Thread Series DesignatorUNS
Trip Release MethodTHERMAL ALL LOCATIONS
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
Cross-Reference Index
Part NumberManufacturer
B77611 Mbda Uk Ltd (GBR)
Reference documents
ReferenceMeaning
9TC2-15 3/2 Design control — primary reference
U.S. Government activity
7910296-01 C/1 Advisory reference — outside the item-of-supply concept
L3 Technologies, Inc. Dba Communication Systems-West Div Communication Systems-West
No interchangeability data on file.
Other items in FSC 5925 — Circuit Breakers
Items in the same Federal Supply class. No interchangeability or substitution relationship is implied.
5925-00-001-1277
CIRCUIT BREAKER
5925-00-001-2809
5925-00-001-2809 · Item name not on file
5925-00-001-3838
CIRCUIT BREAKER
5925-00-001-5748
5925-00-001-5748 · Item name not on file
5925-00-001-5926
5925-00-001-5926 · Item name not on file
5925-00-001-5938
5925-00-001-5938 · Item name not on file
5925-00-001-5942
CIRCUIT BREAKER
5925-00-001-5977
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-086-7424?

NSN 5925-01-086-7424 is a Circuit Breaker, manufactured by Mbda Uk Ltd, classified under FSC 5925, Circuit Breakers. Status: active.

What part numbers are listed for NSN 5925-01-086-7424?

NSN 5925-01-086-7424 has 1 manufacturer part number on file: B77611 (Mbda Uk Ltd).

What are the specifications of B77611?

Key specifications for B77611: Bushing Length: 0.250 INCHES NOMINAL IN; Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 120.0 AC ALL LOCATIONS. 30 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-086-7424 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com