PartsTable TECHNICAL DATA SHEET
NSN 5925-01-080-5755Government record, cited

Circuit Breaker5925-01-080-5755

NSN 5925-01-080-5755 · NIIN 010805755
FSC 5925 — Circuit Breakers · FSG 59 — Electrical and Electronic Equipment Components
Government record, cited
Also searched as  5925-01-080-5755 · 5925010805755 · NIIN 010805755 · 01-080-5755 · FSC 5925 Circuit Breakers · MIL-PRF-83383/4 · M83383/04-05
Nearby stock numbers  ·
Features
  • Circuit Breaker — FSC 5925
  • Reset Method: MANUAL
  • Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS
  • Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC AND 30.0 DC ALL LOCATIONS
  • Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S)
  • Switch Terminal Type: TAB, SOLDER LUG
  • Frequency in Hertz: 400.0 ALL LOCATIONS
  • Fragility Factor: MODERATELY RUGGED
Identification
  • NSN: 5925-01-080-5755
  • NIIN: 010805755
  • FSC: 5925 — Circuit Breakers
  • FSG: 59 — Electrical and Electronic Equipment Components
General Description

The Circuit Breaker, cataloged under National Stock Number 5925-01-080-5755, is classified within Federal Supply Class 5925 (Circuit Breakers) of the Electrical and Electronic Equipment Components group. Government technical data includes 27 specifications, cited from the U.S. Government catalog. 2 additional reference documents (drawings, advisory and superseded references) are recorded in the U.S. Government catalog. 3 items share a part number with this NSN in the catalog (possible match — not a government interchangeability claim). Current acquisition status: Active.

Technical Specifications
ParameterValue
NSN5925-01-080-5755
Item NameCircuit Breaker
FSC / FSG5925 / 59 — Circuit Breakers
StatusACTIVE
Reset MethodMANUAL
Internal Trip Release ConfigurationSERIES TRIP ALL LOCATIONS
Operating Voltage Type and Rating Per Pole in Volts200.0 AC AND 30.0 DC ALL LOCATIONS
Mounting Facility Type and Quantity4 UNTHREADED HOLE(S)
Switch Terminal TypeTAB, SOLDER LUG
Frequency in Hertz400.0 ALL LOCATIONS
Fragility FactorMODERATELY RUGGED
Body StyleRECTANGULAR DIMENSIONAL ENVELOPE
Switch Voltage Rating and Type in Volts115.0 AC AND 28.0 DC
Ultimate Trip Rating of Continuous Current Rating Per Pole in Percent138.0 ALL LOCATIONS
Switch Location and Position DesignationINTERNAL AT POLE THREE
Circuit Protection TypeOVERCURRENT ALL LOCATIONS
Storage TypeGENERAL PURPOSE WAREHOUSE
Unthreaded Mounting Hole Diameter0.167 INCHES MINIMUM AND 0.177 INCHES MAXIMUM IN
Pole Quantity3
Maximum Continuous Load Current Rating Per Pole20.0 AMPERES AC AND 20.0 AMPERES DC ALL LOCATIONS
Trip Release CharacteristicTIME DELAY ALL LOCATIONS
Maximum Interrupting Capacity Current Type and Rating Per Pole in Amps50000.0 AC AND 50000.0 DC ALL LOCATIONS
Specification/standard Data81349--83383/04-05 GOVERNMENT SPECIFICATION
Trip Delay Time in Seconds Per Rated Continuous Current14.000 MINIMUM AT 200 PCT AND 80.000 MAXIMUM AT 200 PCT ALL LOCATIONS
Switch Current Rating and Type in Amps3.0 AC AND 1.5 DC
Inclosure Protection Type for Which DesignedCORROSION RESISTANT AND FUNGUS RESISTANT AND HERMETICALLY SEALED
Test Data Document81349-MIL-C-83383 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
Switch Contact ArrangementSINGLE POLE, DOUBLE THROW
Trip Release Ambient Temp Rating25.0 CELSIUS NOMINAL ALL LOCATIONS DEGC
Terminal Type and Quantity6 THREADED STUD
Main Contact Tripping Mechanism TypeTRIP FREE
Lifecycle & Compliance
Acquisition StatusACTIVE
DEMIL CodeDEMIL A — No Demilitarization Required
HazardPossible hazard — SDS may be required (DLA HMIC P)
Criticality CodeX
⇄ Related Items 3
Each row states its source: a government interchangeability/replacement code, or a possible match on a shared part number.
5925-01-250-8887 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)
5925-01-385-1627 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)
5925-01-420-3986 POSSIBLE MATCH
CIRCUIT BREAKER
Possible match (shared part number)
Cross-Reference Index
No manufacturer part numbers on file in the U.S. Government catalog.
Reference documents
ReferenceMeaning
MIL-PRF-83383/4 4/1 Identification reference
U.S. Government activity
M83383/04-05 2/2 Government specification standardization
U.S. Government activity
Related Parts
5925-01-250-8887POSSIBLE MATCH
CIRCUIT BREAKER
5925-01-385-1627POSSIBLE MATCH
CIRCUIT BREAKER
5925-01-420-3986POSSIBLE MATCH
CIRCUIT BREAKER

Frequently Asked Questions

What is NSN 5925-01-080-5755?

NSN 5925-01-080-5755 is a Circuit Breaker, classified under FSC 5925, Circuit Breakers. Status: active.

What NSN replaces 5925-01-080-5755?

3 possible matches (shared part number, not a government interchangeability claim): 5925-01-250-8887, 5925-01-385-1627, 5925-01-420-3986. Verify interchangeability with system specifications before substitution.

What are the specifications of 5925-01-080-5755?

Key specifications for 5925-01-080-5755: Reset Method: MANUAL; Internal Trip Release Configuration: SERIES TRIP ALL LOCATIONS; Operating Voltage Type and Rating Per Pole in Volts: 200.0 AC AND 30.0 DC ALL LOCATIONS; Mounting Facility Type and Quantity: 4 UNTHREADED HOLE(S). 27 specifications are documented in the U.S. Government catalog.

Is NSN 5925-01-080-5755 hazardous material?

Possible hazard — SDS may be required (DLA HMIC P). Hazard information on this page is shown exactly as it appears in the DLA record.

Sources

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-16.

U.S. Government catalog: edition PUBLOGDVD v12.0.0 (OCT 2026), edition date 2026-10-01, retrieved 2026-10-18.

✓ Data cited from the U.S. Government catalog; commercial cross-references from OEM and certified industry sources.
PartsTable Design LLC · partstable.com